Mixing pump RITMO L plus FC-230V Overview – Operation
Mortar pressure gauge
36
2020-11-09
34.3
Watering the mixing zone
Fig. 62: Watering the mixing zone
NOTE!
The pump must generally be flushed with water.
Flushing with water makes it easier for the pump to
start up.
1. Keep the water flow button (1) pressed for approx. 2 seconds
until the head of the rotor is covered with water.
35 Mortar pressure gauge
Fig. 63: Mortar pressure gauge
DANGER!
Operating pressure too high!
Machine components can fly open in an
uncontrolled manner and injure the operator.
Do not operate the machine without the mortar
pressure gauge.
Only use mortar hoses with a permissible
operating pressure of at least 40 bar.
The burst pressure of the mortar hose must be
at least 2.5 times the operating pressure.
36 Hazardous dust
Fig. 64: Dust mask
WARNING!
Danger of health problems due to dust!
Inhaled dust can lead to long-term lung damage
or other health problems.
NOTE!
The machine operator or the person working in
the dusty area must always wear a dust mask
when filling the machine.
The decisions of the Committee for Hazardous
Materials (AGS) can be read in the Technical
Rules for Hazardous Substances (TRGS 559).
1