Mixing pump RITMO L plus FC-230V Overview – Operation
Putting the machine into operation
38
2020-11-09
41 Putting the machine into operation
41.1 Checking the mortar consistency
Fig. 68: Consistency inspection pipe
1. Connect consistency inspection tube to the mortar
pressure gauge.
2. Place a bucket or tray below the consistency inspection tube.
Item number: 20104301 Consistency inspection tube 25M-part.
41.2 Switching on the RITMO L plus with material
1 3 2
Fig. 69: Switching on
1. Turn selector switch (1) left to position “With water”.
2. Turn potentiometer (2) for motor speed / material volume to
position 7 (readjust as required).
3. Turn selector switch (3) Pump motor directions of rotation to
the right (machine starts).
4. Check material consistency at consistency inspection tube (4).
5. Switch off machine at selector switch (3) (middle position).
6. Remove consistency inspection tube (4) and clean.
42 Potentiometer
Fig. 70: Potentiometer
If the RITMO is switched on/off with the remote control within
short time intervals, the mortar consistency will fluctuate.
The solenoid valve opens from 35Hz. This means that no
water can be supplied in the potentiometer positions 1-4.
(Parameter value 11 – 75Hz with “B” pump)
(Parameter value 10 – 55Hz with “SD” pump)
4