Mixing pump RITMO L plus FC-230V Overview – Operation
Compressed air supply
40
2020-11-09
44 Compressed air supply
44.1 Connecting the air hose
Fig. 74: Connecting the air hose
1. Connect compressed air hose (1) to air fitting
.
DANGER!
Never undo hose couplings while the compressed
air hose is pressurised.
44.2 Connecting the spray gun
2
3
1
4
Fig. 75: Spray gun
1. Connect compressed air hose (1) to the spray gun (2).
2. Make sure that the air valve (3) on the spray gun is closed.
3. Connect spray gun (2) to the mortar hose (4).
44.3 Switching on the air compressor
Fig. 76: Switching on the air compressor
1. Plug connector plug for air compressor (1) into the blue
safety socket (2).
NOTE!
This small compressor may only be operated with
fine plaster device 25 mm, 25-M-part 4 mm air nozzle
for DT4.8 short item number 00111804 or with fine
plaster device 25 mm 25-M-part 4mm air nozzle 30°
600 lg item number 00097283.
44.4 Switching on the vibrator
Fig. 77: Connect the vibrator
NOTE!
If the material is not to slide subsequently in the
material hopper, the vibrator can be connected.
1. Plug the connector of the vibrator (1) into the grey
safety socket (2).
2
1
1
3
2
1