Mixing pump RITMO L plus FC-230V Overview – Operation
Measures to be taken in the event of a water supply failure
44
2020-11-09
Fig. 87: Spray gun
Item number: 20 19 59 00
Description: Spray gun reinforcing fine and reinforcement plaster
Fig. 88: Mortar hose
Item number: 00021100
Description: RONDO grout pressure hose 25 mm, 10 m
Hydraulic connection
Item number: 00037491
Description: RONDO 25 mm 10 m with rotary coupling
You can find further mortar hose accessories at
47.2 Working with pastes
Fig. 89: Blind cap
1. Disconnect the connector plug from the air compressor.
2. Uncouple water hose (1) from the mixing tube add close
both water inlets on the mixing tube with blind cap (2).
3. The paste can be filled into the material hopper.
3 5 4
Fig. 90: Pastes
4. Turn selector switch (3) right to position “Without water”.
5. Turn potentiometer (4) for motor speed / material volume to
position 3 (readjust as required).
6. Turn selector switch (5) Pump motor directions of rotation to
the right (machine starts).
48 Measures to be taken in the event of a water supply failure
NOTE!
The machine can be supplied with clean water
from a container using a pressure booster pump
(item number 00493686) (see page 24, Fig. 40).
2
1