Mixing pump RITMO L plus FC-230V Overview – Operation
Measures to be taken in the event of a power failure
46
2020-11-09
50.2 Discharging mortar pressure
Fig. 93: Checking the mortar pressure
DANGER!
Overpressure on the machine!
When opening machine components, these can fly
open in an uncontrolled manner and injure the
operator.
Only open the machine if the pressure has fallen
to “0 bar”.
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes
and face.
Therefore:
Never look into the spray gun.
Always wear protective goggles.
Always position the machine so that you cannot
be hit should mortar escape.
Cover working area with foil.
1. Open air tap on the spray gun.
2. Check the mortar pressure gauge (1) to see if the pressure has
fallen to “0 bar”. If necessary, discharge any mortar pressure by
unscrewing the screws (2) slightly.
3. Tighten screws (2) again.
50.3 Switching on the machine again after a power failure
2
1 3
1
Fig. 94: Undervoltage trigger
NOTE!
The RITMO L plus is equipped with an undervoltage
trigger. In the event of a power failure, the system
must be started as follows.
1. Turn the selector switch (1) to the “Zero” position (middle position).
2. Close air tap on spray gun.
3. Turn the main switch (2) to the “
I
” position.
4. Turn potentiometer (3) for motor speed / material volume to
position 7 (readjust as required).
5. Turn the selector switch (1) to the right.
6. The RITMO L plus starts up again as soon as the air valve on
the spray gun is reopened.
NOTE!
In the event of a prolonged power failure,
the RITMO L plus and the material hoses
should be cleaned immediately.
1
2