Mixing pump RITMO L plus FC-230V Overview – Operation
End of shift / Cleaning
2020-11-09
53
53.3 Switching on the machine after removing a blockage
2
1 3
1
Fig. 100: Switching on RITMO L plus
1. Selector switch (1) at “Zero” position (middle position).
2. Close the air tap on spray gun.
3. Turn the main switch (2) to the “I” position.
4. Turn potentiometer (3) for motor speed / material volume to
position 7 (readjust as required).
5. Turn the selector switch (1) to the right.
6. The RITMO L plus starts up again as soon as the air valve on
the spray gun is reopened.
54 End of shift / Cleaning
54.1 Switching off the energy supplies
Securing against restarting
DANGER!
Danger of death due to unauthorised restarting!
When working on the machine, there is a danger of
unauthorised switching on of the electrical supply.
This puts those in the danger area at extreme risk.
Before starting work, switch off all electrical power
supplies and secure them against being switched
back on again.
54.2 Cleaning RITMO
CAUTION!
Water can enter sensitive machine parts!
Before cleaning the machine, seal all openings
where water could enter and impair the safety
and functions of the machine (e.g.: electric motors
and control boxes).
NOTE!
Do not aim the water jet at electrical components,
such as the gear motor or control box.