Mixing pump RITMO L plus FC-230V Overview – Operation
End of shift / Cleaning
56
2020-11-09
54.7 Inserting the mixing tube cleaner
Fig. 106: Inserting the mixing tube cleaner
1. Insert cleaner shaft and mixing tube cleaner (1) into
the mixing tube.
NOTE!
Insert mixing tube cleaner (1) with the scrapers
pointing downwards.
Fig. 107: Cleaner shaft seat
NOTE!
When inserting the cleaner shaft make
sure that the cleaner shaft (2) engages
in the head of the rotor (3) and when
closing the motor flange that it correctly
engages in the coupling claw (4).
54.8 Cleaning the mixing tube RITMO
Fig. 108: Cleaning RITMO
1. Close motor tilt flange (1) with gear motor.
2. Close quick fastener (2).
3. Insert 10-pole connector plug (3).
4. Turn the main switch (4) to the “I” position.
5. Turn potentiometer (5) for motor speed / material volume to
position 4.
6. Turn selector switch (6) Pump motor directions of rotation to
the right (machine starts).
7. Allow the machine to run for approx. 5-10 seconds until
the mixing tube is cleaned.
8. Turn the selector switch (6) to the “Zero” position
(middle position).
9. Pull out 10-pole connector plug (3).
10. Undo quick fastener (2) and tilt motor to the side.
11. Take mixing tube cleaner with cleaner shaft out of
the material hopper.
1
3
4
6
2
1
3
2
4
5