Mixing pump RITMO L plus FC-230V Overview – Operation
Measures to be taken if there is a risk of frost
60
2020-11-09
4
Fig. 120: Opening the outlet tap
4. Open outlet taps (4) on the fitting block.
5. Allow water to drain off and close outlet taps again.
NOTE!
Make sure that the water fully flows out of
the water manifold.
57.1 Blowing the water manifold dry
Fig. 121: Connecting the air hose
1. Connect air hose with Geka coupling and EWO coupling to
the compressed air flange (1) and to the water connection (2).
57.2 Blowing the water manifold RITMO L plus dry
Fig. 122: Blowing the water manifold dry
1. Plug connector plug for air compressor (1) into the blue socket.
2. Turn the main switch (2) right to the “
I
” position.
3. Keep the water flow button (3) pressed for approx. 10 seconds.
4. The water is blown out of the manifold with compressed air.
5. Open all water valves and blow out with compressed air again.
6. Pull out connector plug (1).
7. Turn the main switch (2) to the position “0”.
1
2
1
2
3