Mixing pump RITMO L plus FC-230V Overview – Operation
Maintenance
62
2020-11-09
Securing against restarting
DANGER!
Danger of death due to unauthorised restarting!
When working on malfunctions, there is a danger of
unauthorised switching on of the electrical supply.
This puts those in the danger area at extreme risk.
Therefore:
Before starting work, switch off all electrical power
supplies and secure them against being switched
back on again.
58.3 Environmental protection
Observe the following environmental protection guidelines
when carrying out maintenance work:
Remove used, leaking or excess grease from all manual lubrication
points and dispose of it correctly according to the applicable local
regulations.
Collect used oil in suitable containers and dispose of it according to
the applicable local regulations.
58.4 Maintenance plan
The next sections describe the maintenance tasks required
for optimal, problem-free operation.
Provided no increase wear can be identified during regular
inspections, reduce the required maintenance intervals as
appropriate for the actual signs of wear.
For questions regarding maintenance tasks and intervals,
contact the manufacturer (see service address on page 2).
NOTE!
The maintenance is limited to a few checks.
The most important maintenance task is thorough
cleaning after use.
Interval
Maintenance task
To be performed by
Daily
Clean/replace the dirt trap screen in the water inlet.
Operator
Weekly
Clean/Replace intake filter of the compressor.
Service technician
2 weeks
Clean/replace the dirt trap screen in the pressure reducer. Service technician