Mortar pressure manometer
26
2019-12-11
Fig. 34: Water removal valve
NOTE:
The
specifications
of
the
material
manufacturer must be observed here, e.g.,
Knauf MP75 water requirement approx.
600l/h.
Connect water hose (6) at water inlet (7) for the rubber mixing
zone.
18 Mortar pressure manometer
Fig. 35: Mortar pressure manometer
DANGER!
Too high operating pressure!
Machine
components
can
bounce
uncontrollably and injure the operator.
– Do not operate the machine without a
mortar pressure manometer.
– Use only mortar hoses with an approved
operating pressure of min. 40 bar.
– The burst pressure of the mortar hose must
reach at least 2.5 times the value of the
operating pressure.
19 Operating the machine
19.1 Checking mortar consistency
Fig. 36: Consistency checking tube
1.
Connect the consistency checking tube to the mortar
pressure manometer.
2.
Place a basket or tub under the consistency checking
tube.
Article No. 20104301 Consistency checking tube 25M-section.
5
7
6