Mixing pump RITMO XL 400V Overview – Operation
Measures against danger of frost
2019-12-11
37
25.1 Blowing water fitting dry
Fig. 65: Connecting air hose
1. Connect air flange with Geka coupling and EWO coupling
to compressed air connection (1) and water connection
(2).
Fig. 66: Blowing water fitting dry
2. Set main reverse switch (3) to position "I".
3. Turn the selector switch of the pressure boosting pump (4)
to the "0" position.
4. Press the green pushbutton (5) Control voltage "ON".
5. Activate air compressor (6).
6. Press water upstream button (7).
7. The water is now blown with compressed air out of the
fitting (for approx 1/2 minutes).
8. Open all water valves and blow out with compressed air
again.
9. Switch off compressor (6).
10. Set main reverse switch (3) to position "0".