Mixing pump RITMO XL 400V Overview – Operation
Measures during water failure
2019-12-11
45
Fig. 73: Loosening nuts.
2. Detach the nuts (1) on the tie rod first at the bottom on both sides,
so that possible residual pressure can escape fully.
3. Detach coupling (2) on mortar hose and clean mortar hoses
immediately.
4. Rotate the nuts (1) fully from the tie rod.
Fig. 74: Cleaning pump.
5. Press the rotor (3) out of the stator (4) and clean.
6. Clean pressure flange (5) or remixer (ROTOMIX or
ROTOQUIRL).
7. Clean mixing zone and mixing coil with water and scraper.
8. Reassemble pump fully.
30 Measures during water failure
NOTE:
The strainer (Article No. 00136619) can be used to
supply clean water to the machine from a tank (see
Page 24 Fig. 31).
31 Maintenance
31.1 Safety
Personal
The maintenance jobs described here cannot be performed
by the operator, unless denoted otherwise.
Some maintenance jobs may be performed only by
specially trained mechanics or exclusively by the
manufacturer.
Jobs on the electrical system may in principle be performed
only by electricians.
1
1
5
2
3
4