Mixing Pump RITMO XL FU 230/400 reversible Overview – Operation
Description of assemblies
2019-05-13
17
13.2 Undercarriage with compressor and control cabinet
Fig. 9: Undercarriage
Undercarriage with control cabinet.
14 Description of assemblies
14.1 Overview of control cabinet
Fig. 10: Control cabinet module
14 13
12
Fig. 11: Connection 230V - 400V
1. Main reverse switch is simultaneously emergency-stop
switch
.
2. Selector switch Compressor "ON / OFF".
3. Pushbutton Control voltage "ON / OFF".
4. Selector switch Operation with water (as mixing pump),
without water (only as pump).
5. Motor speed material volume.
6. Yellow control lamp Change director of rotation.
7. Yellow control lamp 230V operation.
8. Red control lamp Motor fault.
9. Selector switch Release pump (reverse flow).
10. Pushbutton upstream water flow.
11. Sight glass for frequency converter.
12. Connection for power 400V, 3-phase, 32A
or with adapter
Connection for power 230V, 1Phase, 16A.
13. Connection for air compressor.
14. Connection for pressure boosting pump 230V, 1Phase.
11
10
9
8
7
1
2
3
4
5
6