Mixing Pump RITMO XL FU 230/400 reversible Overview – Operation
Clearing hose blockages
2019-05-13
51
44.1 Change the direction of rotation of the mixing pump motor in case of
blockages in the hose
Fig. 74: Change direction of rotation
1. Turn the selector switch (1) for the air compressor to position "0".
2. Turn main switch (2) to position "I".
3. Press the green push button (3) control voltage “ON”.
4. Turn selector switch pump motor (4) counterclockwise to reverse
direction. (Water supply is automatically interrupted) until the
pressure on the mortar pressure gauge drops to "0 bar".
44.2 Risk of injury to due overpressure
2
1
Fig. 75: Checking the grout pressure
DANGER!
Overpressure on the machine!
When opening machine components, these can
fly open in an uncontrolled manner and injure
the operator.
Only open the mortar hoses if the mortar pressure
gauge (1) indicates the pressure has fallen to “0 bar”.
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes
and face.
Therefore:
Always wear protective goggles.
Protective clothing, protective gloves, safety shoes,
ear protection.
Always position the machine so that you cannot be
hit should mortar escape.
1. Undo both nutss (2) on the pressure flange slightly to ensure
the residual pressure can escape.
2. As soon as the pressure has dropped to “0 bar”, tighten the nuts (2)
again.
3
Fig. 76: Detaching the coupling
NOTE!
Immediately clean the mortar hoses.
3. Cover coupling connections with tear-resistant film.
4. Release cam lever (3) and hose connections.
5. Remove blockage by tapping or shaking at the point of
the blockage.
6. If necessary, introduce a flushing hose into the mortar hose and
flush out the material (PFT flushing hose item no. 00113856).
2
3
1
4