Mixing Pump RITMO XL FU 230/400 reversible Overview – Operation
Decouple mortar hose
54
2019-05-13
46.2 Coupling the water hose
Fig. 81: Water hose
1. Couple water hose (1) to the mixing tube.
46.3 Coupling the water hose
Fig. 82: Opening the motor tilt flange
NOTE:
There should be no material in the material container
and the mixing tube. The safety grid should not be
removed while performing cleaning jobs.
1. Pull out 10-pin connector (1).
2. Open the quick release fastener (2) on the motor tilt flange
and tilt the motor.
NOTE:
While performing cleaning jobs and during motor
transport, the housing with the safety cover (3) must
be closed (protection against humidity).
Fig. 83: Remove the mixing shaft
3. Remove the mixing shaft (4) and clean it.
4. Clean the mixing zone with a spatula.
46.4 Insert the mixing tube cleaner
Fig. 84
: Inserting the mixing tube
cleaner
1. Take out the mixing tube cleaner (1) and cleaning shaft (2)
from the holding device.
2. Insert the cleaning shaft and the cleaning tube cleaner into
the mixing tube.
NOTE:
Insert the mixing tube cleaner with the scraper in
the downward direction.
1
1
3
2
4
2
1