Mixing Pump RITMO XL FU 230/400 reversible Overview – Operation
Maintenance jobs
60
2019-05-13
Interval
Maintenance job
To be performed by
daily
Clean/replace brass sieve in the water inlet.
Operator
weekly
Clean/replace suction filter of the compressor.
Service mechanic
2 weeks
Clean/replace dirt trapping sieve in the pressure
reducer.
Service mechanic
49 Maintenance jobs
49.1 Air compressor DELTA 2 230V
Fig. 98: Compressor
Execution by a service mechanic.
See BAL air compressor DELTA 2 230V Art. No.00199667
49.2 Dirt trapping sieve
Fig. 99: Dirt trapping sieve in the water
inlet
Check dirt trapping sieve in the water inlet daily:
1. Take out dirt trapping sieve from the Geka coupling.
2. Clean dirt trapping sieve.
3. Replace sieve if there are thick dirt deposits.
4. Reinsert sieve
.
Dirt trapping sieve Geka coupling: Article No. 20152000
Execution by operator:
49.3 Dirt trapping sieve
2
1
Fig. 100
: Dirt trapping sieve
1. Unscrew the sealing bolt (1) of the pressure reducing valve.
2. Take out dirt trapping sieve(2) and clean (once every two
weeks).
3. Replace dirt trapping sieve if there are thick dirt deposits.
4. Insert dirt trapping sieve and tighten sealing bolt.
Dirt trapping sieve for pressure reducer: Article No. 20156000
Execution by a service mechanic