Turn on pump motor to the right. Nothing will happen and that’s ok. You are ready to go. To start spraying turn the
air switch on at the end of the spraying nozzle.
The air switch is now the start/stop switch.
To adjust spraying width
adjust air tube at the end of the spraying nozzle.
While pumping check pressure in mortar hose on the pressure gage which is on the Rotor Stator nozzle. Should be
MAX 1 bar of pressure per meter of mortar hose. If more than that then motor is working too hard.
If Amps are too high machine will turn itself off. If machine turns itself off then mix is too dry, hose is plugged,
speed is too fast, wrong mixing product hose is too long or water pressure is too low. To adjust mixture again
simply adjust water volume in small amounts. Give it a minute to go through the hose before you see the new
mixture consistency.
If no power try pushing
GREEN
switch on again. A safety stop was probably triggered. Or if the amps were too
high and stopped the machine, open cabinet and push reset button.
If using pre-mixed wet mixture turn water on/off switch to the off position (right).
Do not get water in the dry bin.
If the mortar hose gets plugged and will not unplug as explained in the directions in step 14, then turn off water
on/off switch and run pump motor in reverse for
1-2 seconds only
. This should release pressure from inside hose so
you can remove hose from the Rotor/Stator nozzle and clean. Remove dry material inside dry bin to make sure no
water has gotten inside. When clean replace everything, turn back on water on/off switch and try again.