Check pressure in mortar hose. Pressure should be zero. If pressure is not zero then run machine in reverse for a
few seconds until pressure is zero. When pressure is zero disconnect mortar hose.
Mortar hose pressure gage
Disconnect spraying nozzle and clean with water.
Insert 2 small
orange
cleaning balls into end of mortar hose. Connect mortar hose to water outlet on RITMO XL
with special hose adapter. Turn on water until small balls come out other end of hose. Do it two times. Hose is now
clean. Clean outside of mortar hose.
Special hose adapter
RITMO XL water outlet
Connect water hose to water outlet on RITMO XL. Open top of dry mixing bin and rinse thoroughly. Close top. Turn
RED
start
button on, Push
GREEN
power button on, turn on pump motor and run machine for a few seconds to
clean out water in mixing bin. Turn off pump motor when done.