MAINTENANCE
WARNING!
Do not clean system with steam sprayer or high-pressure cleaner.
Clean emulgator filter
The emulgator filters must be cleaned every 14 days.
To clean the emulgator filters, proceed as follows:
Cut off power to the system by turning the main reversing switch to
“0”
.
Observe the pressure display at the compressor!
Check if pressure hose is without pressure.
Pressure display is at
“0”
.
Motor and drive by turning hand wheel to position
“FLAP CLOSED”
Close silo/container flap.
Turn hand-0 automatic switch
(2)
to position
“HAND”
Turn main reversing switch
(3)
to position
“I”
.
Press operating switch
(1) “ON”
.
Blow conveying container empty.
Turn main reversing switch
(3)
to position
“0”
.