PFT Conveying Pump SWING L Overview – Operation – Spare Parts Lists
Check direction of rotation
28
14/09/2021
Fig. 23:
Blind plug
Fill the SWING L material hopper with about one litre of wallpaper
paste so that the screw pump does not run dry during startup and
inspection.
WARNING!
Before operation can begin, either pull off the blind
plug (3) or press the remote control.
27.6 Mortar pressure gauge
Fig. 24:
Connect the mortar pressure
gauge
DANGER!
Operating pressure too high!
Machine components can fly open in an
uncontrolled manner and injure the operator.
Therefore:
Do not operate the machine without the mortar
pressure gauge.
Only use conveying hoses with a permissible
operating pressure of at least 40 bar.
The burst pressure of the mortar hose must be at
least 2.5 times the operating pressure.
28 Check direction of rotation
28.1 Only for machines with fixed speed
1
5
3
4
2
Fig. 25: Switching on
1. Turn the main reversing switch (1) to the “I” position.
2. Green indicator light (2) for control voltage must light.
3. Activate the green illuminated button (3) (control voltage “ON”).
4. If the direction of rotation is wrong, switch off the machine at the
red push button (4) control voltage "OFF".
NOTE!
If the direction of rotation is wrong:
The main reversing switch is locked in the zero
position by sliding the selector plate (5) to the left or
right in a presetting and thus the direction of
rotation is selected. If the switch is on the left, the
switch can be switched back to zero, but is blocked
for the right position
3