PFT
Conveying Pump SWING L
Overview – Operation
– Spare Parts Lists
Establish air
14/09/2021
31
30.3 Switch on the SWING L
1
Fig. 33: SWING L FU Wahlschalter
Fig. 34: SWING L
1. Switch on the SWING L FU (Fig. 33), turn the selector switch (1) to
the right.
2. Switch on the SWING L (Fig. 34), press the green push button (2)
(control voltage "ON").
3. Let the SWING L run until the wallpaper paste has completely
escaped at the end of the mortar hose.
4. Catch wallpaper paste in a suitable container and dispose of
according to regulations.
5. As soon as mortar emerges at the end of the mortar hose, switch
off the machine.
6. Turn the selector switch (1) to position "Zero" (middle position).
7. Switch off the machine at the red push button (3) control voltage
"OFF".
NOTE!
Never let the pump run dry, otherwise the service life of
the pump will be shortened considerably.
31 Establish air supply
31.1 Connect the air hose
Fig. 35:Connect the air hose
1. Depending on the application, connect the air hose to the air
compressor.
DANGER!
Never loosen hose couplings as long as the air hose
is not depressurized.
32 Spraying gun
32.1 Connecting the spraying gun
2 3 1
4
Fig. 36: Spraying gun
1. Connect the compressed air hose (1) at the spraying gun (2).
2. Ensure that the air tap (3) is connected to the spraying gun.
3. Connect the spraying gun (2) at the mortar hose (4).
DANGER!
Never detach hose couplings if the material hoses
are under pressure (check mortar pressure gauge)!
Mixing material can escape under pressure and
lead to serious injuries, especially eye injuries.
2
3