34.3 Brief interruptions
1
Fig. 43:
Closing the air valve
NOTE!
Always observe the setting time of the material to be
processed:
Clean the system and mortar hoses depending on
the setting time of the material and the length of the
interruption (pay attention to outside temperature).
The guidelines of the material manufacturers have
to be observed regarding breaks.
1. Close the air valve (3) on the spraying gun.
2. The machine stops.
3. By opening the air valve (3), the machine will start running
again.
34.4 For longer work breaks / breaks
1
Fig. 44: Close the air cock
2
3
Fig. 45: Switch off
1. Close the air cock (1).
2. Switch off the machine.
3. Press the red push button (2) control voltage "OFF".
4. Turn the selector switch (3) to position "Zero" (middle position).
34.5 Switch off air compressor 400V (accessory)
Abb. 46: Air compressor 400V
1. Switch off the air compressor.
2. Open the air cock on the sprayer.
DANGER!
Risk of injury from compressed air!
Caution residual pressure.