PFT Conveying Pump ZP 3 XL MIX Part 2 Overview – Operation - Spare Parts Lists
Subassembly Description
14
Fehler! Formatvorlage nicht definiert.
3.9 Operating Modes Multiple Contact Switch
Fig.11: Multiple contact switch "0"
The multiple contact switch for external vibrator can be switched in
three different operating modes:
Position "0"
Vibrator is ready for operation, no function.
Fig.12: Multiple contact switch "Hand"
Position "Hand"
In position "Hand" (scanning) the vibrator operates continuously,
so long as the switch is activated.
Fig.13: Multiple contact switch "Automatic"
Position "Automatic"
Vibrator runs on automatic pulse / pause.
3.10 Remote Control Operation
Fig.14: Remote control
Working with Spray Device:
If the control plug from the pressure switch (1) at the switch cabinet
(2) is connected, the machine can be switched On or Off on the
spray device.
Working with Remote Control Cable:
If the remote control cable is connected to the switch cabinet, the
machine can be switched On or Off via the control cable.
Fig.15: Connect the dummy plug
Operation without Remote Control:
Connect the dummy plug.
Machine must be turned On or Off per hand at the switch cabinet.
If the connector is pulled, the control current will be interrupted.
1