PFT Conveying Pump ZP 3 XL MIX Part 2 Overview – Operation - Spare Parts Lists
Troubleshooting Tasks
32
Fehler! Formatvorlage nicht definiert.
10.8 Turning Off
Fig. 38: Turning Off
DANGER!
Danger due to Exiting Material!
According to accident prevention regulation of the
employer’s insurance association, persons allocated the
task of eliminating blockage must wear personal protective
gear (protective goggles, safety gloves) for safety reasons
and must position themselves such that they cannot be hit
by exiting material. Other persons may not linger around.
Turn the main reversal switch to position "0".
10.9 Changing the Rotation Direction of Pump Motor
Fig. 39: Changing the rotation
direction
The main reversal switch is locked in position "0" by pushing the selection
slide (1) to the left as preset and thus the rotation direction is preselected.
If the switch is on the left, the switch can be turned back to zero, but it is
blocked in the right position.
Fig. 40: Turning Off
Switch on the press button - operation ON / OFF (2).
Let the pump motor shortly run backwards until the pressure on the mortar
pressure manometer drops to 0 bar.
Switch off the main reversal switch.
Push the selector slide to the right.
10.10 Loosening the Coupling Connections
Fig. 41: Hose blockage
Cover the coupling connections with a strong plastic film.
Release the cam lever and hose connections.
HINT!
The mortar hose must be cleaned immediately.
Release the clogged material by knocking or shaking.
In case of emergency, rinse the material hoses with a rinsing hose
and finally apply slurry anew.
Then connect the hoses with one another again.