PFT Conveying Pump ZP 3 XL MIX Part 2 Overview – Operation - Spare Parts Lists
Cleaning
Fehler! Formatvorlage nicht definiert.
33
10.11 Earlier Damage to Material Hose
HINT!
Should the pressure in the material hose exceed 60 bar
briefly, exchanging the mortar hose is recommended because
externally invisible initial damage could occur to the tube.
10.12 Pauses
Fig. 42: Turning Off
HINT!
Generally observe the curing time of the material to
be processed.
Working pauses under 10 minutes:
Switch off the equipment via the press button - operation ON/OFF.
Longer pauses:
Switch off the system using the main switch.
Clean the system and material hoses depending on the curing time
of material.
While doing so, observe the ambient temperature.
11 Cleaning
11.1 Cleaning the Drum Mixer and ZP 3 XL
Fig.43: Clean ZP 3 XL MIX
Cleaning:
Prior to every lengthy working pause and at the end of daily work,
the feed pump ZP 3 XL must be cleaned thoroughly.
DANGER!
Excess Pressure on the Machine!
Before cleaning work, switch off the mixer by doing
the following (with brush, rag, scraper, etc.)
manually.
Do not touch inside the drum by hand.
While doing cleaning work, do not put ZP 3 XL
MIX into operation.
When protective covers are removed for cleaning,
they must be reinstalled properly at the end of
work.
During indirect cleaning, do not direct the water jet
on the motor.