(5) When the white level adjustment is terminated abnormally
Screen T45
Function No.
Display
Scanner status
Displays
“c”.
The adjustment has terminated abnormally.
Note: The major reason of abnormal termination is incorrect setting of the test sheet. Set the test sheet correctly and try the
magnification adjustment again.
<Available buttons at Screen T45>
Function
button: Displays error information (Screen T46)
Send to button: Terminates this mode and returns to Screen T04.
Screen T46
Function No.
Display
Description
Countermeasure when abnormal
termination frequently occurs
1: media error
The tested sheet may not be a specified one. Please
confirm the test sheet is good.
It seems Lamp or Optical unit is faulty. Replace
defective parts.
<Available buttons at Screen T46>
Send to button: Terminates this mode and return to Screen T04.