fi-5530C/fi-5530C2
IMAGE SCANNER
MAINTENANCE MANUAL
APPR.
TITLE
DRAW.
No.
Feb.23, 2007
05
Section 4-9-4
4-9-4. Replacing the Lamp SR (for ADF backside)
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-5
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit and Upper cover by referring to Sections from
4-7-1
,
4-7-2
and
4-7-5
.
(2) Remove the Optical unit by referring to
Section 4-9-3
.
(3) Disconnect the Lamp cable connector from the Inverter SR.
(4) Release three craws from the Reflector, and then remove the assembly of Reflector and Lamp.
<Mounting>
(1) Follow the removing procedure in reverse. Take care that slim cable is routed as follows.
(2) After mounting the Lamp SR, perform the following adjustment:
■
Offset adjustment (Refer to
Section 5-1-4
)
■
White balance adjustment (Refer to
Section 5-1-5
)
■
Magnification adjustment (Refer to
Section 5-1-3
)
Slim cable (shall be
routed under thick
cable)
Connector
Three claws
Assembly of Reflector and Lamp SR
Inverter SR
Three claws