4-10-3. Replacing the Dust cover
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-2
for the part number of the replacement part.
<Removing>
(1) Remove Pick roller by referring to
Section 1-8-3
. Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear
cover, Upper cover and Guide A ASSY by referring to Sections from
4-7-1
to
4-7-6
.
(2) Remove a screw that fixing FG cable, and remove a connector
from Cover open sensor. Then remove the sensor cable from a
hole of chassis.
(3) Remove two screws from Base unit.
(4) Release two upper craws and two lower craws, and
then remove Dust cover taking care that the cables
from Dust cover shall not be pulled by force.
Reference: Dust cover includes following parts.
Lamp SR, Inverter SR, US sensor, US PCA, HK Ring SR
Lower craw (another
one is in opposite side)
Base unit
Two screws
Upper craws (two)
Do not pull the cable by force.
FG cable
A connector of Cover
open sensor
A hole of chassis
Sensor Cable