background image

Segurança e harmonia

ININTERRUPTA

19

Uninterruptible Power Supply

PH 7266 | PH 7288 | PH 7210

EN

2. Installation and setup

UNPACKING

The box should contain the following:

-  UPS,
-  user manual.

OVERVIEW

The UPS provides automatic voltage regulation for inconsistent utility power, and provides battery 
backup during power outages, and ensures consistent power to your computer system.

HARDWARE INSTALLATION GUIDE

1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at 

least 8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. 
Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit 
plugged into an AC outlet. The unit will charge in both the on and off position.

2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered 

data storage device (Zip drive, Jazz drive, Tape drive), etc. into the battery power supplied outlets. 
DO  NOT  plug  a  laser  printer,  copier,  space  heater,  vacuum,  paper  shredder  or  other  large 
electrical device into the battery power supplied outlets. The power demands of these devices will 
overload and possibly damage the unit.

3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch 

outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical 
demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.

4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit 

will "beep".

5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To 

correct this, turn the UPS off and unplug at least one piece of equipment from the battery power 
supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the 
UPS on.

6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7.  To  store  your  UPS  for  an  extended  period,  cover  it  and  store  with  the  battery  fully  charged. 

Recharge the battery every three months to ensure battery life.

Summary of Contents for PH 7210

Page 1: ...Sistema de Alimenta o Ininterrupta Uninterruptible Power Supply Manual de uso Manual de utiliza o User Manual ES PT EN Seguridad y armon a ININTERRUMPIDA SAI ONLINE VA 1060 880 2017 PHASAK UPS ONLINE...

Page 2: ...ESPA OL Seguridad y armon a ININTERRUMPIDA Seguridad y armon a ININTERRUMPIDA PORTUGU S INGL S 09 01 17 Sistema de Alimentaci n Ininterrumpida PH 7266 PH 7288 PH 7210 GARANT A GARANTIA GUARANTEE 25...

Page 3: ...importante sobre seguridad 2 Instalaci n y configuraci n 2 1 Empaquetado 2 2 Funciones del equipo 2 3 Gu a de instalaci n del SAI 3 Funciones b sicas 3 1 Panel Frontal 3 2 Panel Trasero 4 Soluci n de...

Page 4: ...osici n directa al sol o junto a fuentes de calor tales como calentadores radiadores etc Atenci n No Conecte el SAI a dispositivos tales como equipos m dicos equipos de soporte vital hornos de microon...

Page 5: ...la bater a NO conecte una impresora l ser copiadora calentador aspiradora trituradora de papel u otro dispositivo el ctrico en las tomas suministradas por la bater a Los requisitos de energ a de esto...

Page 6: ...encienda la alarma 2 Indicador LED Este indicador se iluminar cuando el SAI est en funcionamiento PANEL TRASERO 3 Cable de alimentaci n Cable para conexion a una toma CA 4 Conectores Schuko soporte de...

Page 7: ...l SAI no se enciende La unidad no est conectada a una salida AC Apague el SAI espere 10 segundos y vuelva encenderlo La unidad debe de estar conectada a una toma de 230V 50 60Hz Las bater as est n gas...

Page 8: ...gundos Se produjo el corte de corriente el ctrica el SAI est suministrando energ a de la bater a Dado que el intervalo de la se al sonora es corto indica que la bater a se est quedando sin carga y pro...

Page 9: ...esti n de las funciones del SAI Siga el siguiente procedimiento para instalar el software Proceso de Instalaci n 1 Descarge el software Power Guide desde nuestro website http www phasak com descargas...

Page 10: ...ible Protecci n de sobrecarga CARACTER STICAS F SICAS Medidas W x H x D CONDICIONES AMBIENTALES 0 40 C Humedad relativa de trabajo 0 90 Temperatura de trabajo GESTI N Cargar Reiniciar PH 7210 1060VA 6...

Page 11: ...Aviso de seguran a importante 2 Instala o e configura o 2 1 Conteudo da embalagem 2 2 Vis o geral 2 3 Instala o de hardware 3 Opera es Basicas 3 1 Painel Frontal 3 2 Vista Traseira 4 Solu o de problem...

Page 12: ...os e evite exposi o directa ao sol ou junto a fontes de calor tais como aquecedores etc Aten o N o Ligue a UPS a equipamentos tais como equipamentos m dicos equipamentos de suporte de vida fornos de m...

Page 13: ...uma impressora a laser copiadora aquecedor aspirador trituradora de papel ou outro dispositivo el trico nas tomadas fornecidas pela bateria As exig ncias de energia desses dispositivos ser o excessiv...

Page 14: ...inal sonoro quando o alarme for ligado 2 Indicadores LED O LED fica ligado quando a UPS est em funcionamento VISTA TRASEIRA 3 Cabo de alimenta o Cabo para ligar a uma tomada para fornecer energia UPS...

Page 15: ...UPS n o est ligada a uma tomada Electrica Desligue a UPS Aguarde 10 segundos e ligue novamente a UPS A UPS deve estar ligada a uma tomada Electrica 230VAC 50 60Hz A bateria encontra se danificada Con...

Page 16: ...se o corte de corrente El trica a UPS est a fornecer energia da bateria Dado o intervalo do sinal sonoro ser curto indica que a bateria est a ficar sem carga e em breve ir desligar se Ligado e pisca c...

Page 17: ...energia A interface gr fica do usu rio intuitiva e exibe informa es de energia essenciais Siga o procedimento abaixo para fazer o download e instalar o software Modo de instala o 1 Download Power Guid...

Page 18: ...AMBIENTE 0 40 C Temperatura aconselhada 0 90 Humidade Relativa GEST O Carregar Reiniciar PH 7322 BATERIA Bateria selada com chumbo cido Tempo para carga total 8 hours INDICADORES DE ADVERT NCIA Power...

Page 19: ...Warning 2 Installation and setup 2 1 Unpacking 2 2 Overview 2 3 Hardware installation guide 3 Basic operation 3 1 Front panel 3 2 Rear panel 4 Troubleshooting 5 Definitions for illuminated LED indica...

Page 20: ...nput into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of a...

Page 21: ...NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the battery power supplied outlets The power demands of these devices will overload and possibl...

Page 22: ...ingle short beep when the Alarm is turned on 2 LED indicators This LED is illuminated when the UPS is working REAR PANEL 3 Input Power Cord Cabo para ligar a uma tomada para fornecer energia UPS 4 AC...

Page 23: ...turn on The unit is not connected to an AC outlet Turn the UPS off Wait 10 seconds and then turn the UPS on The unit must be connected to a 120Vac 50 60Hz outlet The battery is worn out Contact Techni...

Page 24: ...ds Utility Failure The UPS is providing battery power to outlets Flash Beep 1 time In Every 2 Seconds Utility Failure The UPS is providing battery power The rapid bee ps indicate the battery will run...

Page 25: ...The graphic user interface is intuitive and displays essential power information at a glance Please follow procedure below to install the software Installation procedure 1 Download Power Guide from th...

Page 26: ...ONMENTAL 0 40 C Operating Temperature 0 90 Operating Relative Humidity MANAGEMENT Auto Charger Auto Restart BATTERY Sealed MaintenanceFree Lead Acid Battery Typical Recharge Time 8 hours WARNING DIAGN...

Page 27: ...iciar da nossa GARANTIA COMPLETA IN SITU DE DOIS ANOS Esta garantia fora da Pen nsula Ib rica ser coberta nas instala es do distribuidor autorizado da marca PHASAK No momento da sua recep o examine o...

Page 28: ...PHASAK 2017 All rights reserved Reproduction without permission is prohibited...