Extending probe cables 

You can extend temperature probe cables to lengths of up to 500 feet. Follow the guidelines below 
and below when extending cables. 

‹

 

Use two-wire 18 AWG jacketed cable. Phason recommends Belden # 9408, Alpha # 5052, or an 
equivalent. Extension cable is also available from Phason. For more information, contact your 
dealer or Phason. 

‹

 

Join the extension cable to the temperature probe cable as shown on the next page. 

‹

 

If the unit operates erratically with the extended probe, run the cable along a different path or 
shorten it. 

C

A

A

C

E

D

F

 

A

 

Slide three pieces of heat shrink tubing over the wires: one for the red wire, one for the black 
wire, and one for both. 

B

 

Strip the ends of the wires and then twist them together. 

C

 

Solder the wires together using rosin-core flux solder—DO NOT use acid core solder.  

D

 

Slide the heat shrink tubing over the solder joints.  

E

 

Shrink the tubing using a heat gun. 

F

 

Your connection should look like this. 

Summary of Contents for MTC-4C

Page 1: ...ode or operates the fans at the idle speed idle mode The MTC 4C is ideal for poultry livestock greenhouse or light industrial buildings Electrical ratings Input 120 230 VAC 60 Hz Variable stage 10 A a...

Page 2: ...fore removing electrical knockouts remove the cover to prevent damaging the control Do not make additional holes in the enclosure this can damage the watertight seal or components and void the warrant...

Page 3: ...bles Do not run the sensor cable beside AC power cables or near electrical equipment When crossing other cables or power lines cross them at a 90 degree angle Service Panel Enclosure C F E B A D Probe...

Page 4: ...e extension cable to the temperature probe cable as shown on the next page If the unit operates erratically with the extended probe run the cable along a different path or shorten it C A A C E D F A S...

Page 5: ...on 3 Turn the Idle Speed knob to the minimum idle speed desired 4 Turn the Temperature knob to the desired temperature Using idle mode 1 Position the jumper as shown in section G on page 3 2 Turn the...

Page 6: ...or acetoxy cure These sealants release acetic acid while curing which can damage the control and will void the warranty 4 Check all wires to make sure they are properly connected and that they are in...

Page 7: ...current rating of the control The fan motor growls To ensure the motor is working disconnect the line at terminal 1 and terminal 4 and then connect these lines together The fan should run at full spe...

Page 8: ...ovide proof of purchase upon request All transportation charges for products submitted for warranty must be paid by the purchaser Except to the extent prohibited by applicable law no other warranties...

Reviews: