© Glentronics, Inc.  06/15

1806066  

4

Visit our website www.stopflooding.com for more information about the PHCC
Pro Series AC pumps and battery backup sump pump products.

Maintenance Check List

Maintenance should be performed 1-2 times per year. 
1. Remove all debris from the the pump strainer and bottom of 

the pit.

2. Remove all debris floating in the water.
3. Remove all debris from the float switch cage.
4. Fill the pit with water.  Make sure pump turns on at the 

intended level.

5. While the pump is running, make sure pump is evacuating water

at a good pace.

6. While the pump is running, make sure a stream of water is

escaping from the air bleed hole.  If not, clear the hole of any
deposits or debris.

7. Unplug the control box from the wall.  Make sure the “AC power

is out” light and alarm sound (DFC2).

Backup Installation

When the power goes out, the PHCC Pro
Series AC sump pumps will not operate.
For protection during a power outage, a
PHCC Pro Series battery backup system
can be installed.  There are three systems
with matching batteries that will provide
protection.  The illustration at right is an
example of a typical battery backup
installation.  

Summary of Contents for Pro S3 Series

Page 1: ...ump pit If a hole is not drilled above the pump an air lock may prevent the pump from operating The hole must be drilled above the water line but below the check valve The optimum size of the hole is different for different pumps Drill a 1 8 3 2mm hole in the discharge pipe for the S3 Series and S5 Series pumps DO NOT use sump pumps in pits handling raw sewage salt water or hazardous liquids S3 S5...

Page 2: ...p or down the lift rod 4 To avoid debris from pouring onto the float it should be positioned on the side of the discharge pipe opposite the drain tile 5 Once the float switch is in the desired position securely tighten the hose clamp Note The cable from the switch must remain outside the hose clamp Connecting the Pump and Controller Deluxe Dual Float Controller Model DFC2 1 Mount the controller to...

Page 3: ...medies set forth are exclusive and in lieu of all other warranties remedies and conditions whether oral written statutory express or implied GLENTRONICS INC disclaims all statutory and implied warranties including without limitation warranties of merchantability and fitness for a particular purpose and warranties against hidden or latent defects to the extent permitted by law GLENTRONICS INC will ...

Page 4: ...level 5 While the pump is running make sure pump is evacuating water at a good pace 6 While the pump is running make sure a stream of water is escaping from the air bleed hole If not clear the hole of any deposits or debris 7 Unplug the control box from the wall Make sure the AC power is out light and alarm sound DFC2 Backup Installation When the power goes out the PHCC Pro Series AC sump pumps wi...

Reviews: