background image

Montage- und Installationsanleitung 

Mounting and installation instruction

 

22.04.2021 

5 / 6 

91293.docx 

Rev.: 1.26 

 

Waste Disposal 

 

This product 

must not

 be disposed in normal household waste! Please 

ensure a professional disposal or return the product to: 
phg Peter Hengstler GmbH + Co. KG, 
Dauchinger Straße 12, 
78652 Deißlingen, Germany 

 

General information 

 

Reading distance 

The normal reading distance depends on the reader system, the installation environment and from the data carrier model. 
Information about the respective reading distances in optimal installation environment (non-metal environment), refer to the relevant 
data sheet of the reader. In case of mounting the reader on metal may slightly reduce the reading distance. 

 
Influence (reduction) of the reading distance 

The reading distance can be influenced by completely different factors. On the one hand, it is influenced by the medium (the data 
carrier) and on the other by the ambient conditions of the antenna and the data carriers. 
This is a list of elements that reduce the reading distance: 

 

Shielding the data carrier by metal materials, for example, EC card in the wallet, key tag on a bunch of keys 

 

No optimum coupling, i.e. the antenna surface of the data carrier is vertical (90°) to the reader’s antenna surface 

 

Data carrier itself 
- key tag (small active antenna surface) 

“poor resonance of the data carrier (IC card / key tag) 

- combined ID card (e.g. LEGIC

®

 / inductive , mifare/inductive, etc.) 

 

Metal  in  the  “active”  surface of  the  HF  field.  The transmitting  energy  is  reduced.  This point is  mainly  relevant,  when the 
reader components are integrated in metal cover plates (including metal pillars etc.).

 

 

Electrical interference 

The readers can interfere with each other or be influenced by other systems and interference sources.     The readers can interfere 
with each other at a distance of two to three times of the reading distance. High energy interference sources in the area of the 
modulation and carrier frequencies might also disturb transmission. We do not recommend to supply the readers through switch 
mode power supplies, since superimposed frequencies on the supply voltage might also have a negative effect on the relevant 
reader system. This must be checked in the individual case. It should be observed that the interference spectrum of switch mode 
power supplies might be changed through parameters such as temperature, input voltage, power to be supplied, etc. 
 

Installation of data cables and supply cables 

A sufficient cable cross-section is to be ensured for supplying the readers (in particular over larger distances). Since power 
consumption of the individual systems is pulsed in some cases, short voltage dips cannot be detected by a conventional multimeter 
(digital or analog). But such voltage dips might lead to a "POWER-ON-

RESET“ in the reader component, which might result in 

disruptions to communication. 
The determination of the correct power supply and the cable cross-sections should be based on a maximum power consumption. 
Care must be taken to ensure that the input voltage (measured on the reader) complies with the technical data of the reader. 
 
 

Care and cleaning instruction 

The use of hard or sharp objects (rings, fingernails etc.) can cause scratches and damage the device. 
Wipe the device with a soft lint-free cloth, or one that has been lightly dampened with water. 
The use of caustic liquids such as benzene, thinners, alcohol, solvents, or any kind of abrasive cleaners  
will lead to surface deterioration and damage.

 

 
 

 