Extend 3 phase 5 wires AC input cable from conduit of concrete base, AC cable
expose at least 400mm and these 5 wires should be with ring terminals ( L1,
L2, L3 & N: Inner Diameter: 10.5mm, Outer Diameter: 22mm & PE: Inner Diam
-
eter: 6.4mm, Outer Diameter: 22mm) . The conductor cross sectional area of
input power wires should be not less than 50mm². If internet connection is via
Ethernet, a 1500 mm Ethernet cable is necessary to install via the conduit to
the charger.
Lift the charger on concrete base, pull the input cable through bottom hole of
charger; fasten 8 pcs of M12 screw nuts and 4 pcs of M12 washers on 4 pcs
of M12 screw of concrete base (2 nuts for each screw) to secure the chargers.
Then fix the base cover (in the accessory pack) in charger base.
STEP 2.
METHOD 1.
3.5.2 Two Methods of Fixing DSYx601 Charger
If use L-brackets to fix charger, secure L-brackets on the cement base by 4 pcs
of M12 expansion bolts.
METHOD 2.
15