47
Note:
•
Before switching off main breaker to begin maintenance, please record the
status code number on the LCD monitor.
•
After switching off the key switch the circuit before the main terminal is still
hazardous. Only visual inspection can be operated.
•
Maintenance of the DC Fast Charger shall be conducted only by a qualified
technician.
•
After opening the front door of the DC Fast Charger, turn off the main breaker
and auxiliary breaker before any maintenance work.
•
Replace the ventilation filter every six to twelve months.
•
Please confirm the main power junctions are tightened every month, and rotate
cables testing when the power off. If any main power screw is loose will be
resulted in damage on charger or smoke on the connections. Please confirm
screw torque requirement table.
Summary of Contents for DC EVSE 60KW
Page 2: ......
Page 10: ...2 5 Direction of cooling Airflow Air Out Air In 7 ...
Page 15: ...Remove these 4 pcs of fixing M12 screws STEP 3 12 ...
Page 55: ...52 NOTE ...
Page 56: ...NOTE ...
Page 57: ...NOTE ...
Page 58: ...Manufacturer Contact Info Sticker www phihong com tw ...