background image

 

 

 

Phihong USA Corporation

 

 East Coast Engineering Center 

 630 Johnson Ave. Suite 102, Bohemia, NY 11716 

 Tel: (631) 610-2289 

www.Phihong.com

 or 

www.Midspans.com

  

13 

 
2.8    Technical Specifications 

 
 
Mechanical Specifications: 
 

z

 

Length: 228mm (8.9 inch) 

z

 

Width:  198mm (7.8 inch) 

z

 

Height:  44.5mm (1.75 inch) 

z

 

Weight: 1.0Kg(2.5lbs) 

 
Environmental Specifications:  
 
Temperature    

 

 

 

 

       Relative Humidity  

      - Operating:   0°C to +40°C 

 

 

             - Operating:    5% to 90% 

      - Non-Operating:   -25°C to +65°C                                   - Non-Operating:    5% to 90% 
 
Electrical Specifications: 

 

 

*Please contact sales 

at 510-445-0100

 for more info. 

 

Parameters Specifications 

AC Input voltage rating

 

100VAC to 240VAC

 

AC Input voltage range

 

90VAC to 264VAC

 

AC Input current

 

3.0A (rms) at Max. load nominal line 

AC Input frequency:

 

47Hz to 63Hz 

Max. In-rush current

 

30A for 115VAC at Max. load 
60A for 230VAC at Max. load

 

 

Model 

Output 
Voltage 

Power 
per port  

 Power 
Total Output 

Supported Functions 

POE125U-8-R 

50V 

15.4W 

125W 

Supports IEEE signature  

POE125U-8-C-R 50V 

15.4W  125W 

Supports IEEE/Legacy signature 

POE125U-8-N-R 50V 

15.4W  125W 

Supports IEEE/Legacy 
signature, SNMP function 

POE125U-4AT-R 56V 

33.6W  135W 

Supports IEEE/Legacy signature 

POE240U-4UP-R 56V 

60W 

240W 

12.5K 

detection 

Summary of Contents for POE125U

Page 1: ...0 Phihong PoE125U and PoE240U Midspan User Manual Rev A1 ...

Page 2: ... the software and hardware used on the Midspan The information is held to be accurate and reliable from time of print Please be advised that product development and revisions are still in course of action Phihong cannot be held responsible for involuntary error exclusions inaccuracies or following changes of printed material Phihong reserves the right to make changes to products and to their speci...

Page 3: ...es 10 2 4 Connecting Power Cables 10 2 5 Powering Up 10 2 6 LED Indicators 10 2 7 Rack Mounting Installation 12 2 8 Technical Specifications 13 3 Troubleshooting 14 Appendix A Optional NIC Interface for N model Only 15 A1 NIC Interface Setup 15 A2 Phihong GUI Installation 24 A3 How to use the Phihong GUI with the NIC Midspan 25 A4 Midspan GUI 28 A5 How to update the SNMP Firmware 33 A6 How to use ...

Page 4: ...span 8 Figure 2 Data Power top row Data bottom row 8 Figure 3 NIC Connector 8 Figure 4 Rear Side of Midspan 8 Figure 5 Rack Mounted Midspan 11 Figure 6 Rack mounting bracket and screws 11 Figure 7 GUI Main Window 27 Figure 8 System Setup Control 27 Figure 9 System Information and Port Commands 28 Figure 10 Port Description 29 Figure 11 LED Key Port Status 30 Figure 12 Parametric Information 31 ...

Page 5: ...gineering Center 630 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 4 List of Tables Table 1 LED Indicator 11 Table 2 Electrical Specifications 12 Table 3 Troubleshooting 13 Table 4 SNMP MIB 45 ...

Page 6: ...ith all procedures and instruction s can be found in the Midspan User Manual To download a copy of the Manual visit www Phihong com 3 To prevent the Midspan from overheating do not operate the product in an area that exceeds the maximum recommended ambient temperature of 40 ºC Allow at least 3 to 4 inches of clearance around all ventilation openings 4 In order to support the Midspan weight do not ...

Page 7: ...e vor dem Anschließen des Midspan Device an eine Energiequelle einschließlich der erforderlichen Anschlussleitungen die Setup Anleitung für Ihre Midspan Hardware in Kapitel 2 genau durch Dieses Verfahren wird zusammen mit allen weiteren Vorgängen und Anweisungen im Benutzerhandbuch für das Midspan Device beschrieben Sie können das Benutzerhandbuch unter www Phihong com herunterladen 3 Um das Midsp...

Page 8: ...s für Gleich oder Wechselstrom muss jederzeit zugänglich sein da er als Haupttrenngerät für das Produkt dient 8 Trennen Sie das Produkt immer erst von der Stromquelle bevor Sie Wartungs oder Reparaturarbeiten daran durchführen 9 Entsorgen Sie dieses Produkt gemäß aller geltenden Gesetze und Vorschriften Ihres Landes und der EU falls Sie sich in einem Land der EU befinden ...

Page 9: ...11716 Tel 631 610 2289 www Phihong com or www Midspans com 8 2 Midspan Hardware Setup 2 1 Physical Hardware Appearance Front Side of Midspan Fig 1 Front side of Midspan Fig 2 Data Power top row Data bottom row Fig 3 NIC Connector N Model Only Rear Side of Midspan Figure 4 Rear side of Midspan ...

Page 10: ...omply with SEV ASE 1011 Denmark The supply plug must comply with section 107 2 D1 standard DK2 1a or DK2 5a United Kingdom The Midspan is covered by General Approval section 16 16 060 NS G 12345 J100003 for indirect connection to a public telecommunication system France and Peru IT equipments cannot power this device In the case of an IT powered device the unit needs to be powered by 230 V through...

Page 11: ...idspan Ethernet cables are not included AC Power Cord may be order separately 2 5 Powering Up Midspan is powered by the power cord In order to apply or remove power to from the Midspan connect or disconnect the AC power cable to from the AC power connector on the rear side of the unit With AC power applied the unit starts up and the internal fans are active The device runs through a quick power on...

Page 12: ...s stay off PoE PD connected Off Off No PoE PD connected On Off PoE PD connected On blinking periodically On blinking periodically Fault condition wrong signature detected or overload or short circuit condition etc Port POE LED Top Row LED only POE125U 4AT R POE240U 4UP R On blinking periodically Off PoE PD connected but PD is dropped off as not enough load current OFF OFF NIC card is not working B...

Page 13: ...Mounting Installation Fig 5 Rack Mounted Midspan front Fig 6 Rack mounting bracket and screws Position the Midspan on the rack Arrange the mounting bracket to the corresponding screw holes on the Midspan Keep the screw area visible to insert screws and then tighten the screws Note Screws and brackets can be ordered separately please contact sales at 510 445 0100 ...

Page 14: ... Please contact sales at 510 445 0100 for more info Parameters Specifications AC Input voltage rating 100VAC to 240VAC AC Input voltage range 90VAC to 264VAC AC Input current 3 0A rms at Max load nominal line AC Input frequency 47Hz to 63Hz Max In rush current 30A for 115VAC at Max load 60A for 230VAC at Max load Model Output Voltage Power per port Power Total Output Supported Functions POE125U 8 ...

Page 15: ...that AC power cord is in good condition 3 If solution 1 2 are true then disconnect the AC power cord and reconnect Observe Port LEDs to verify proper power up Port LED do not light green 1 Port maybe disabled and needs to be enabled using the GUI Ensure Ports are enabled then Save Flash Parameters 2 Assure Ports are connected to a Network Others Please verify the following 1 Power is applied to th...

Page 16: ...GUI to communicate with the Midspan 1 Visit www Midspans com to download latest SNMP MIB for the NIC interface Example SNMP MIB file please check our website for updates If you choose to use your own SNMP console please rename the SNMP MIB text file to the file extension that matches your SNMP Console Follow the instructions for your SNMP Console to install the MIB file Please check the Phihong we...

Page 17: ... bit environment and is used to setup the IP address subnet mask and MAC address of your SNMP device For more advance setup settings use Internet Explorer or another Internet Browser NOTE Your IP Address may be different from the example shown below 3 Execute etm exe Ethernet Manager tool 4 Assuming the connection path between your PC and the Midspan is adequate the Ethernet Manager tool will dete...

Page 18: ...nson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 17 6 For Advance Setup Configuration click Config Æ Device Settings OR type the IP address in your Internet Browser Your Internet Browser will open with the following window ...

Page 19: ...ohnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 18 The default Password administrator NOTE If you forget your login password please contact our Application Engineering Group for further instructions 7 Controller Setup ...

Page 20: ...ing Center 630 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 19 NOTE If you change the Setup password please write it down in a safe place for your reference Click Update to save your configurations ...

Page 21: ...s of numbers assigned by the Network server DHCP mode Enabled or user defined DHCP mode Disabled Subnet mask 255 255 255 0 Four groups of numbers assigned by the Network server DHCP mode enabled or user defined DHCP mode disabled Gateway address 192 168 0 1 Four groups of numbers assigned by the Network server DHCP mode enabled or user defined DHCP mode disabled Network link speed Auto Auto 10 ful...

Page 22: ...ng a SNMP Firmware update Disable 0 0 0 0 0 0 0 0 0 0 0 0 Access control Accessible address 0 0 0 0 The default setting Disable sets the Access control to allow all IP address access capability If the Access control is Enable only the IP addresses listed in the Accessible addresses will be able to access the SNMP commands Accessible address is the IP addresses that are allowed to read and write SN...

Page 23: ...e Windows Firewall settings to allow incoming Network Connections by adding a specific program i e the SNMP Console 8 If you wish to run your SNMP device in Static mode you can also configure your IP address and Subnet Mask through the Ethernet Manager tool etm exe Click Config Æ IP Address NOTE From the Controller Setup menu your DHCP client setting must be set to Disable 9 DHCP client Dynamic or...

Page 24: ...rnet Protocol TCP IP to view the properties If the DHCP client is set to Disable it is in Static mode The user has the option to manually set the IP Address Subnet mask and Gateway Address for your PC If the DHCP client is Enable it is in Dynamic mode Obtain an IP address automatically The Network will automatically set the IP Address Subnet mask and Gateway Address for your PC ...

Page 25: ...2 Phihong GUI Installation Please locate and download the file Phihong GUI Installation from the Phihong website www midspans com Please follow the Installation Wizard to install the Phihong GUI for your model Note Please refer to the Phihong website to insure you are installing the latest version of the Phihong GUI Example shown is using the POE125U GUI ...

Page 26: ...top or from your Start menu Step 1 Choose Connection Type SNMP LAN WAN Æ select AutoScan IP address Set Auto Scan will search for the IP address of Phihong PoE125device starting from the IP address of circled by 1 and ending the search at 2 NOTE Please take in account that each IP address will require 10 seconds to detect For faster detection please use the Ethernet Manager tool etm exe to detect ...

Page 27: ...Coast Engineering Center 630 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 26 Step 2 Select Auto Scan If a Phihong PoE125U Device is found the GUI will link to the device automatically ...

Page 28: ...on Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 27 NOTE The IP address set will be saved internally for the next use Please refer to section A 4 Midspan GUI of this document for the full description of the Phihong GUI features ...

Page 29: ...02 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 28 A4 Midspan GUI A4 1 GUI Main Window Figure 7 GUI Main Window A4 2 GUI System Control The System Control panel on the GUI supports the main system level parameters for the µP Figure 8 System Setup Control ...

Page 30: ... seconds to respond to the commands selected DO NOT click or check any commands simultaneously If a command is selected more than once within two seconds the GUI may not respond properly If the GUI fails to respond wait five seconds and then click Reset GUI click Reset GUI again if necessary Verify that the System Status reads 0 which indicates that there is a good connection The Save Parameters t...

Page 31: ...n will be set for the system To make this permanent the user must click Save Parameters to Flash A4 4 GUI Port Description The Port Description panel shows 8 ports Each section specifies the individual port descriptions for the system Figure 10 Port Description Changes to the port configuration in this section can be enacted when the user clicks the Send Port Control button It will send the port i...

Page 32: ... make this permanent the user must click Save Parameters to Flash If Detect Legacy Signature checkbox is selected all ports are enabled and the firmware will try to detect legacy devices By default legacy detection is disabled The message in blue states that the Legacy Detect is Enabled Figure 16 Click Send Port Control to send the command to the system To make this permanent the user must click S...

Page 33: ...s that are displayed Discovery R ohms This value represents the discovered resistance R of the port in ohms Current mA This value represents the current I of the port in milliamps Voltage V This value represents the voltage V of the port Power mW This value represents the power of the port in milliwatts Class Current mA This value represents the class current of the port in milliamps Determined Cl...

Page 34: ...or example purposes only please check www Midspans com for current updates 1 Please refer to Step 1 of the NIC Interface Setup section Use the Ethernet Manager tool etm exe to detect the IP address 2 Visit www Midspans com to download the SNMP firmware and Upload program The eUpg32 exe is a Firmware Update Utility that runs under the Windows 32 bit environment In this example eUpg32 exe and the SN...

Page 35: ...t Engineering Center 630 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 34 4 Assign corresponding IP Address of the NIC Interface Midspan found with ETM exe 5 Load the SNMP firmware file bin ...

Page 36: ... Engineering Center 630 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 35 6 Click Program to update the SNMP firmware Verify that the SNMP firmware successfully updated and close the program ...

Page 37: ...ed to retrieve general information about your NIC Interface Midspan Please use the Ethernet Manager Tool etm exe to verify the IP address of your NIC Interface Midspan Point to the Æ Æ Æ Click NOTE Assure the connection path between your PC and the Midspan Your IP Address and Midspan Setup Password may be different from the example shown below Please assure you are using the last password stored i...

Page 38: ...0 Johnson Ave Suite 102 Bohemia NY 11716 Tel 631 610 2289 www Phihong com or www Midspans com 37 Setup the Host Address IP address of the NIC Interface Midspan Please use the same password from the Controller Setup login The default password is administrator ...

Page 39: ... 11716 Tel 631 610 2289 www Phihong com or www Midspans com 38 If you entered the correct password you will be connected Type to enter the Help Menu NOTE If you are Idle for a few minutes you will be disconnected Please reconnect by clicking on the Call icon Please reenter the login password ...

Page 40: ...ity set string set community set public or private set default set default set IP x x x x set IP 192 168 1 107 set subnet x x x x set subnet 255 255 255 0 set accctrl on off set accctrl on Allow access for up to four IP address set accctrl off default setting all access allowed Set acclist n x x x x Accessible address is the IP addresses that are allowed to read and write SNMP commands to the NIC ...

Page 41: ... the Midspan model show system show system Trapemu port trap_number Trapemu 1 24 1 7 select trap to emulate Trap numbers defined 1 poePortHWFailTrap 2 poePortPeakOverCurrentTrap 3 poePortOverloadTrap 4 poePortDiscoveryFailTrap 5 poePortClassificationFailTrap 6 poePortDisconnectTrap 7 PoePortVoltageFailTrap help After a specific change the NIC Interface Midspan will automatically reboot The IP addr...

Page 42: ...tem firmware and SNMP Firmware is the latest Step 3 Type reboot Verify that the Midspan is rebooting all LEDs will flash Step 4 Click on the disconnect icon Step 5 If you wish to reconnect use the Ethernet Manager Tool etm exe to verify the IP address of the NIC Interface Midspan Note Your IP Address and Midspan Setup Password may be different from the example shown above Please check the Phihong ...

Page 43: ...r Setup is Disabled Allowing all access Connection within the same Network Domain Please refer to thee diagram above for Building 1 For instance The NIC Interface Midspan is connected to the Network Domain of 192 168 1 xxx located on the 1st floor All Computers connected to the Network Domain of 192 168 1 xxx can communicate with the NIC Interface Midspan The NIC Interface Midspan remains connecte...

Page 44: ...twork Domains Please refer to the diagram above Building 2 For instance The NIC Interface Midspan is connected to the Network Domain of Building 1 192 168 1 xxx Building 2 254 168 2 xxx would like to communicate with the NIC Interface Midspan from Building 1 Building 1 must configure the main Network Server to allow access from an outside source in this case Building 2 Building 1 must be able to s...

Page 45: ... poeSystemNumberOfChannel INTEGER Read only Number of ports available in the system 1 3 6 1 4 1 24852 2 2 8 0 poeSystemProductPartNumber INTEGER Read only Number of ports 1 3 6 1 4 1 24852 2 2 10 0 poeSystemFirmwareVersion DisplayString Read only System firmware version for the POE 1 3 6 1 4 1 24852 2 2 11 0 poeSystemDescription DisplayString SIZE 0 10 Read Write System Description max length of 1...

Page 46: ...e port current exceeds the maximal value since the attribute was last cleared The value both 3 indicates that both underCurrent and overCurrent since the attribute was last cleared The value ok 4 indicates neither an undercurrent or an overcurrent condition has been detected since the attribute was last cleared This attribute is cleared through the poePortCurrentStatusClear action 1 3 6 1 4 1 2485...

Page 47: ... 0 65535 Not accessible Uniquely describes the group the Trap Control is located 1 3 6 1 4 1 24852 2 4 1 2 1 24 poeTrapsControlEnable INTEGER trapsDisabl ed 1 trapsEnabld ed 2 Enables and Disables the Trap from the Agent 1 3 6 1 4 1 24852 2 5 1 poePortHWFailTrap NOTIFICATIO N Hardware Failure Trap 1 3 6 1 4 1 24852 2 5 2 poePortPeakOverCurrentTrap NOTIFICATIO N Peak Over Current Trap 1 3 6 1 4 1 2...

Reviews: