Philadelphia Scientific
®
iBOS
®
Pro 6 Series Operations Manual
Page 13 of 17
troubleshooting, focus your attention on the following columns:
•
Connected Not Charging
•
No Battery Connected
•
Quarantine
•
Unknown
4.2.1 Connected Not Charging
This could mean that a battery has just been connected and that the charger has not had time to turn on,
but it could also mean that there is an issue with the battery or charger such that the charger will not start
its charge cycle.
•
If any charger ID’s are listed in the column marked “Connected Not Charging”, check to see if the
charger indicates a fault.
•
Confirm that the amber
LED is illuminated on the Sentinel™, and that a battery is connected.
•
If the display and all indicator lights on the charger are blank, check to see if there is power to the
charger.
•
Check to see if the charger is set for a delayed start.
•
If the charger is functioning properly, check the voltage of the battery as some chargers will not
recognize an over discharged battery.
4.2.2 No Battery Connected
The system does not indicate that a battery has been connected.
•
If a charge ID is listed in the column marked
“No Battery Connected”, check to see if a battery is in
the charging slot on the battery rack.
•
If there is a battery, check to see if it is connected to the charger listed.
•
If a battery is connected, look at the amber LED on the Sentinel™ to be sure that it is on.
•
If a battery is connected, and the amber LED is not on,
o
Check the battery connector to be sure that it is not broken.
o
Check the Quick-
Tap on the Sentinel™ to be sure that the pins have penetrated the cable
and are not bent.
4.2.3 Quarantine
The Quarantine column shows the quantity of chargers where a battery has been connected, but the
charger has not started within 24 hours. The system quarantines the battery by taking it out of the queue,
and if the issue is not resolved within 72 hours, the battery is returned to the queue. This time is
Quarantine can be adjusted by the user. (See DOC0023
– iBOS
®
Pro 6 Series Installation Manual for
more details.)
•
If any charger ID’s are listed in the column marked “Quarantine”, check to see if the charger
indicates a fault.
•
Confirm that the amber LED is illuminated on the Sentinel™, and that a battery is connected.
•
If the display and all indicator lights on the charger are blank, check to see if there is power to the
charger.
Quick Tap Installation
Diagram