Before turning on the appliance allow it to stand in its fi nal location for 12 hours, the coolant circuit
will stabilise in this way and no operating problems will occur. Before connecting the appliance to the
power grid check that it is perfectly dry inside – especially in the corners.
Danger warning
The coolant may be highly fl ammable, depending on its composition. The coolant circuit was
hermetically closed and sealed and was tested many times for possible leaks. Any unqualifi ed
tampering with the product may cause a fi re hazard. Check that there is no mechanical interruption
or eff ect on the coolant circulation, namely in the accessible parts around the compressor.
Only professionally qualifi ed persons may work on the cooling system.
Cleaning before use
Check that you have removed from the appliance all adhesive tape used to hold accessories . Then clean all the
inside parts using lukewarm water with a neutral cleaning agent, vinegar or sodium carbonate – in this way
you will remove the characteristic odour of new parts – then dry carefully. Do not use detergents or aggressive
agents, which could damage the surfaces.
Electrical connection
Before connecting the power plug to the power socket, check that:
Your hands are completely dry.
The voltage and frequency shown on the rating label of the appliance corresponds to that in the home
power grid (permitted tolerance from -6% to +6% for nominal voltage, for use with diff erent voltages, use
a voltage changer with the corresponding parameters).
The cord and the plug are not damaged or caught under heavy objects.
The power cord is not excessively tensioned, it is not permitted to use an extension cord.
Do not connect the appliance to a voltage rectifi er (e.g. solar power plant) or use an extension cord.
The appliance must be connected to a working grounding lead. If the power socket of the home
system is not grounded in accordance with the current legal regulations, connect the appliance
after consulting a specialised technician to the grounding lead itself. The manufacturer takes no
responsibility for injuries caused as a result of not following these instructions.
If you do not correctly level the freezer during the installation, the doors may not close shut and seal
properly, which may cause problems with the cooling, ice build up or moisture. Levelling the freezer is
very important.
Level the freezer using the adjustable feet – turn them clockwise to lift the freezer and turn them anticlockwise
to lower the freezer.