background image

1. 

Overview

 

This multimeter is characterized by a compact rugged construction with protective 
 holster and stand. The LCD Screen with 27mm display gives clear readings even 
in low light when the backlight can be switched on. Features include dual slope 
A/D converter using C-MOS technology for auto-zeroing, polarity selection and 
over-range indication. Full overload protection is provided.
Before use you will need to fit a 9V PP3 battery (not supplied) in the compartment 
located on the back of the meter. To open the compartment remove the cross 
headed screw from the lid and lever open, clip the terminal studs over the battery 
terminal caps, close the compartment lid and screw tightly shut.

2. Panel Layout

 

1)  LCD Display 27mm

2)  POWER Switch: Boot Up / Shutdown

3)  Data-hold Switch (HOLD): Pressing this button, the meter enters the auto data hold  

 

mode and “HOLD” is displayed on the LCD.

4)  Back Light Button Switch: Pressing the button turns the backlight on,  

 

pressing it again turns it off.

5)  Function switch indicator lamp

6)  hFE Input Socket

7)  Rotary Switch: use this switch to select functions and ranges

8)  Mechanical blocking system.

9)  V/Ω Input Socket, 20A Input Socket, mA Input Socket & COM Input Socket

SPECIFICATIONS

3.1   GENERAL CHARACTERISTICS

3.1.1  3 ½ digit big LCD max. Indication 1999.

3.1.2   Auto-Zero & Auto-Polarity.

31.3  Overrange: indication of “1” or “-1”.

3.1.4   Low battery indication: “ ”

3.1.5  Power supply: 9V Zinc-carbon battery.

3.1.6  Safety standards: The meter complies with IEC1010 Double Insulation, 

 

 

  Pollution Degree 2, overvoltage Category II.

3.1.7  Protective terminal socket covers prevent operational mistakes

3.1.8  Optimum operating temperature for accuracy: 23ºC±5ºC

3.1.9  Temperature range: Operating: 0ºC to 40ºC Storage: -20ºC to 60ºC

3.1.10 Humidity range:

 

 

  Operating : max 75%RH Storage: max 80%RH

3.1.11 Size: 190mm x 88.5mm x 27.5mm

3.1.12 Weight: Approx 320g (including battery).

31.13  Accessories: Operation manual, Test leads, Temperature test probe & 

 

 

  zip-up case.

3.2 MEASUREMENT SPECIFICATION

Environment :

Temperature : 23ºC±5ºC relative humidity: max 75%

3.2.1 DC Voltage

Range

Resolution

Accuracy

200mV

100µV

±

(0.5% of rdg + 8 digit )

2V

1mV

±

(0.5% of rdg + 8 digits)

20V

10mV

±

(0.5% of rdg + 8 digits)

200V

100mV

±

(0.5% of rdg + 8 digits)

1000V

1V

±

(1.5% of rdg + 8 digits)

Overload Protection : 1000V DC/700Vrms AC on other ranges.

Input impedance : 10MΩ on all ranges

3.2.2 AC voltage (Average sensing. calibreated to rms of sine wave)

3.2.2 AC Voltage

Range

Resolution

Accuracy

2V

1mV

±

(1.5% of rdg + 10 digit )

20V

10mV

±

(1.5% of rdg + 10 digits)

200V

100mV

±

(1.5% of rdg + 10 digits)

700V

1V

±

(2.5% of rdg + 10 digits)

Frequency Range: 40 to 400Hz

Response: average, calibrated in rms of sine wave

3.2.3 DC Current

Range

Resolution

Accuracy

2mA

1µA

±(0.8% of rdg + 8 digits)

20mA

10µA

±(0.8% of rdg + 8 digits)

200mA

100µA

±(1.2% of rdg + 8 digits)

20A

10mA

±

(2.0% of rdg + 10 digits)

Overload protection: 

0.2A/250V fuse 20A/250 fuse 20A up to 15 seconds

Note: [1] 10A range: not fused

3.2.4 AC Current

Range

Resolution

Accuracy

2mA

1µA

±(1.0% of rdg + 8 digits)

20mA

100µA

±(2.0% of rdg + 8 digits)

20A

10mA

±(3.0% of rdg + 15 digits)

Frequency : 40~200Hz

Overload protection : 0.2A /250V fuse,20A/250V fuse 20A up to 15 seconds

3.2.5 Resistance

Range

Resolution

Accuracy

200Ω

0.1Ω

±(1.2% of rdg + 15 digits)

2KΩ

±(0.8% of rdg + 8 digits)

20KΩ

10Ω

±(0.8% of rdg +8 digits)

200KΩ

100

±(0.8% of rdg + 8 digits)

2MΩ

1KΩ

±(0.8% of rdg + 8 digits)

20MΩ

10KΩ

±(2.5% of rdg + 15 digits)

200MΩ

100KΩ

±(5.0% of (rdg-10rdg + 30 digits)

Overload protection :250V DC/250Vrms AC for all range.

3.2.6 Capacitance

Range

Resolution

Accuracy

2nF

1pF

±

(2.5% of rdg + 25 digits)

20nF

10pF

±

(2.5% of rdg + 20 digits)

200nF

100pF

±

(2.5% of rdg + 20 digits)

2µF

1nF

±

(2.5% of rdg + 20 digits)

20µF

10nF

±

(2.5% of rdg + 20 digits)

Overload Protection :36V DC/36Vrms AC for all range

3.2.7 Transistor hFE Test 

Range

Test Range

Test Current / Voltage

hFE

Display reads approx. hFE value 

(0~1000) of transistor under test 

(NPN and PNP Type ) 

Best  Current  approx  10µA 

Voltage approx 3V

3.2.8 Diode test and Audible Continuity Test

Range

Description

Test Condition

Display shows approximate 

forward Voltage of diode.

Forward DC current approx 1.5mA

Reversed DC voltage approx. 3V

Built-in buzzer sounds if 

resistance is less than 80Ω.

Open circuit voltage approx 3V

Overload protection: 250V DC/250Vrms AC

USER GUIDE

 

Digital Multimeter

83003R

Battery 

Compartment

Insert 9V PP3

Reviews: