background image

 

to the instructions for your Z-Wave

TM

 

Certificated Primary Controller to access the 

Setup function, and to Add/Remove/associate devices 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

LED 2-second on, 2-second 
off

 

Add (Inclusion)

 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.    Pressing Include button of PAD07 

three times within 2 seconds will 
enter inclusion mode.

 

Remove 
(Exclusion)

 

1.  Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.  Pressing Include button of PAD07 

three times within 2 seconds will 
enter exclusion mode.

 

3. Node ID has been excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Reset

 

1.  Pressing Include button of PAD07 

three times within 2 seconds will 
enter inclusion mode.

 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable.

 

2.  Within 1 second, press Include button 

of PAD07 again for 5 seconds.

 

3.  IDs are excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Association

 

1.  The PAD07 is an always listening 

Z-Wave device, so associations may 
be added or removed by a controller 
at any time. 

Or    If your controller requires to have 

the PAD07 send a 'node information 
frame' or NIF for associations, then 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAD07 to send its NIF.

 

 

2.    There are two groups for the dimmer.

   

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node 
ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification. 
 

State Type

 

LED Indication

 

Normal

 

Whenever we switch On and off of the PAD07 by On/Off button or RF 
command, the LED will lights up when switch on; whereas LED off 
when switch off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second intervals. 
By pressing On/Off button, it will stop flashing temporarily.

 

Learning

 

When PAD07 is in learning mode, LED flashes on and off alternately 
and repeatedly at 0.5 second intervals.

 

 

 

Manual dim level control :

 

To manually switch on the light, press and release the On/Off button or S1/S2 shortly 

when the light is off. The light will dim from off to the level which was set before switch 

off. To manually switch off the light, press and release the On/Off button or S1/S2 

shortly when the light is on. To adjust the dim level, press and hold the On/Off button 

or S1/S2 until the desired dim level is achieved, then release.   

 

 

Programming

 

1. Basic Command Class / Multilevel Switch Command Class

 

The dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are 

part of the Z-Wave system. If PAD07 is included as a secured node, it will only 

response to the security encapsulation command of BASIC and MULTILEVEL 

SWITCH. 

Summary of Contents for PAD07

Page 1: ...with a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power app...

Page 2: ...ause the PAD07 to send its NIF 2 There are two groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LE...

Page 3: ...will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device reset locally notification When PAD07 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 2 On Off Event Report When on or off state has been changed it will send Multilevel Switch Report to the nodes of Grouping 1 ...

Page 4: ...m down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimmer on The default setting is Last dimmer state 4 Firmware update over the air OTA PAD07 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF ...

Page 5: ...Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject to change and improvement without notice FCC ID RHHPAD07 Warning Do not use Non Dimmable LED lamps DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into th...

Page 6: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Reviews: