background image

Adding to Z-Wave

 Network

There is a button with LED indicator in front of PAD18. It is used

to dim on/off the light and carry out the inclusion, exclusion, reset
or association of PAD18 from Z-wave controller.

When the fist power one, the LED indicator flashes once per

second for 30 seconds. With the SmartStart function, PAD18 will
be automatically included by Z-wave controller.

PAD18 can be operated with any certified Z-Wave™ devices

from different manufacturers in Z-Wave™ network. All non-battery
operating devices act as repeaters to increase the stability and
reliability of the Z-Wave™ network.

The   table   below  provides   an   operation   summary   of  basic   Z-

Wave™ functions. To add/remove/associate PAD18, please refer
to the instruction of certified Z-Wave™ Primary Controller.

Function

Description

Annotation

Without Node ID

New PAD18 does not have Node ID until it is
included by a Z-Wave

 Controller.

LED

 

light

flashes   once   per
second   for   30
seconds.

Add

(Classic Inclusion)

1.

Set Z-Wave™  Controller to inclusion mode
by following the instructions provided by the
controller manufacturer.

2.

Press   the   button   on   PAD18   three   times
within 3 seconds to enter inclusion mode.

SmartStart

1. To   initiate   the   SmartSart   process,   please

type in the first five digits of DSK string or
scan the QR code. The QR Code can be
found on PAD18 or in the box.
Ex:   DSK:   18112-24021-   48001-62259-
57092-27453-08187-47408

2. PAD18 is supported with SmartStart, it can

be added to Z-Wave™ network by scanning
the Z-Wave™ QR code on the product.

3. Without further actions, PAD18 will be auto-

matically   included   in   a   certified   Z-Wave™
Controller with SmartStart inclusion ability in
10 minutes after it turned on.

Remove

(Exclusion)

1.

Set   your   Z-Wave™   controller   to   exclusion
mode by following the instructions provided
by the controller manufacturer.

2. Press   the   button   on   PAD18   three   times

within 3 seconds to enter exclusion mode.

3. Node ID will be excluded.

LED   light   flashes
once   per   second
for 30 seconds.

Reset

1. Press the button of PAD18 four times within

3 seconds and hold the last press until the
LED light turns off.

LED   light   turns
on.

2. Once   the   LED   light   turns   off,   release   the

button within 2 seconds.

LED   light   turns
off.

3. Device has been reset.

LED   light   flashes
once   per   second
for 30 seconds.

Adding a node ID allocated by Z-Wave™ Controller means inclusion. 
Removing a node ID allocated by Z-Wave™ Controller means exclusion.

The situation of including/excluding of the node ID can be checked from the 
Z-Wave™ Controller.

Function Reset: The Reset procedure can only be used when PAD18 cannot 
be recognized by the Z-Wave™ Primary Controller.

3

Summary of Contents for PAD18

Page 1: ...re for firmware upgrade Specification Rating Rating 12 24VDC Max 70mA In Sensor 0 10VDC Push button Switch Potentiometers 100K Out 0 10VDC for controller load RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 4MH 869 85MHz EU 922 5MHz 923 9MHz 926 3MHz JP 920 9MHz 921 7MHz 923 1MHz TW KR Thai SG Transceiver RF Maximum Power Peak 10dBm Peak RF Maximum Power Average 10dBm Averag...

Page 2: ...R TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK For Instruction to http www philio tech com Danger of Electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Locati...

Page 3: ... process please type in the first five digits of DSK string or scan the QR code The QR Code can be found on PAD18 or in the box Ex DSK 18112 24021 48001 62259 57092 27453 08187 47408 2 PAD18 is supported with SmartStart it can be added to Z Wave network by scanning the Z Wave QR code on the product 3 Without further actions PAD18 will be auto matically included in a certified Z Wave Controller wit...

Page 4: ...Wave system PAD18 responds to both Basic Command Class and Multilevel Switch Command Class However if PAD18 is included as a secure node it responds only to the security encapsulation command of Basic Command Class and Multilevel Switch Command Class The Basic Command Class is mapped according to the follow ing table Basic Command Mapped Command Basic Set Value Multilevel Switch Set Value Basic Re...

Page 5: ...nimum level 5 Output Min Level 1 0 0 Maximum level 1 To set dimming level minimum value Dimming level will directly go to 0 when dimming value is lower than the setting value Setting value Cannot be higher than the Maximum level 6 Basic Duration Config 1 2 0 127 Unit second To set dimming finished duration time when physical switch used Ex When setting is 2 it will take 2 seconds from switch on ac...

Page 6: ...e mode 2 Choose the hex file to update the firmware 3 Wait 10 15 minutes for completing the OTA process 4 Result of OTA will show in Z Wave Controller log During the OTA process please DO NOT remove the power otherwise the firmware will be broken and the device will be nonfunctional Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None...

Page 7: ...se limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a particular installation I...

Reviews: