LED Light Indication
The LED light indicates the different modes of the PAD18
State Type
LED Indication
Without
Node ID
Under normal operation, when the PAD18 has not been allocated a
node ID, the LED light will flash on and off alternately at 1-second
intervals. By pressing the On/Off button, LED light will stop flashing
temporarily.
Learning
Flashes when learning is successful
Manual Dimming Level Control
1. Long press the button, the light level will be increased and
decreased, slowly and repeatedly.
2. Short press the button, the light will be on/off to the last light
level.
3. User can set Z-Wave™ Configuration 1 according to different
switch type as following form tells:
Input Switch Type
Config 1 Set Value
Long Press
Short Press
Button on PAD 18
-
Dimming
On / Off
General Switch
0
Dimming
On / Off
Variable Resistor
1
Dimming
-
Z-Wave™ Functions
Basic Command Class and Multilevel Switch Command Class
are two parts of the Z-Wave™ system. PAD18 responds to both
Basic Command Class and Multilevel Switch Command Class.
However, if PAD18 is included as a secure node, it responds only
to the security encapsulation command of Basic Command Class
and Multilevel Switch Command Class.
The Basic Command Class is mapped according to the follow-
ing table.
Basic Command
Mapped Command
Basic Set
(Value)
Multilevel Switch Set
(Value)
Basic Report
(Current Value, Duration)
Multilevel Switch Report
(Value, Duration)
Z-Wave™ Association Groups
PAD18 can be set to send reports to associated Z-Wave™
devices. It supports one association group with five nodes support
for group 1.
For group 1, the dimmer will report
MULTILEVEL_SWITCH_REPORT
SENSOR_MULTILEVEL_REPORT and
DEVICE_RESET_LOCALLY_NOTIFICATION.
1.
Grouping 1 Lifeline (Maximum 5 nodes).
2.
MULTILEVEL_SWITCH_REPORT
When “on” or “off” state has been changed,
It will send Multilevel Switch Report to the nodes of Grouping 1.
3.
SENSOR_MULTILEVEL_REPORT
When sensor is change exceeds threshold.
4.
DEVICE_RESET_LOCALLY_NOTIFICATION
When PAD18 is reset manually, it will send
DEVICE_RESET_LOCALLY_NOTIFICATION to the nodes of group 1.
4