background image

13

Temperature

Offset

2

0

-32768

~32767

Temperature offset 
settings

14

Temperature

Threshold

2

5

1~32767

Temperature reporting 
threshold

15

Max Value

Illuminance

Sensor

4

10000

1~200000

Maximum Illuminance 
Sensor range value

16

Illumination

Offset

4

0

-200000

~200000

Illumination offset 
settings

17

Illumination

Threshold

4

1000

1~200000

Illumination reporting 
threshold

18

General

Threshold

1

5

1~100

General reporting 
threshold

Notice 1: 

Always Reset a Z-Wave™ device before trying to add it

to a Z-Wave™ network.

Notice   2:  

PAD18   can   be   operated   in   any   Z-Wave™   network

which provided by other certified  Z-Wave™ Controllers. All non-
battery operating devices act as repeaters to increase the stability
and reliability of the Z-Wave™ network.

Over-the-Air (OTA) Firmware Update

The device is supported with Z-Wave™ firmware update via OTA.

1.

Set the Z-Wave

TM

 Controller into the firmware update mode.

2.

Choose the hex file to update the firmware.

3.

Wait 10~15 minutes for completing the OTA process.

4.

Result of OTA will show in Z-Wave™ Controller log.

During the OTA process, please DO NOT remove the power,

otherwise,   the   firmware   will   be   broken,   and   the   device   will   be
nonfunctional.

Z-Wave™ Supported Command Class

Command Class

Version

Required Security Class

Z-Wave Plus™ Info

2

None

Security

1

None

Security 2

1

None

Supervision

1

None

Transport Service

2

None

Association

2

Highest granted Security Class

Association Group Information

3

Highest granted Security Class

Device Reset Locally

1

Highest granted Security Class

Firmware Update Meta Data

5

Highest granted Security Class

Indicator

3

Highest granted Security Class

Manufacturer Specific

2

Highest granted Security Class

Multi-Channel Association

3

Highest granted Security Class

Powerlevel

1

Highest granted Security Class

Version

3

Highest granted Security Class

Configuration

4

Highest granted Security Class

SENSOR MULTILEVEL

11

Highest granted Security Class

SWITCH MULTILEVEL

4

Highest granted Security Class

6

Summary of Contents for PAD18

Page 1: ...re for firmware upgrade Specification Rating Rating 12 24VDC Max 70mA In Sensor 0 10VDC Push button Switch Potentiometers 100K Out 0 10VDC for controller load RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 4MH 869 85MHz EU 922 5MHz 923 9MHz 926 3MHz JP 920 9MHz 921 7MHz 923 1MHz TW KR Thai SG Transceiver RF Maximum Power Peak 10dBm Peak RF Maximum Power Average 10dBm Averag...

Page 2: ...R TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK For Instruction to http www philio tech com Danger of Electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Locati...

Page 3: ... process please type in the first five digits of DSK string or scan the QR code The QR Code can be found on PAD18 or in the box Ex DSK 18112 24021 48001 62259 57092 27453 08187 47408 2 PAD18 is supported with SmartStart it can be added to Z Wave network by scanning the Z Wave QR code on the product 3 Without further actions PAD18 will be auto matically included in a certified Z Wave Controller wit...

Page 4: ...Wave system PAD18 responds to both Basic Command Class and Multilevel Switch Command Class However if PAD18 is included as a secure node it responds only to the security encapsulation command of Basic Command Class and Multilevel Switch Command Class The Basic Command Class is mapped according to the follow ing table Basic Command Mapped Command Basic Set Value Multilevel Switch Set Value Basic Re...

Page 5: ...nimum level 5 Output Min Level 1 0 0 Maximum level 1 To set dimming level minimum value Dimming level will directly go to 0 when dimming value is lower than the setting value Setting value Cannot be higher than the Maximum level 6 Basic Duration Config 1 2 0 127 Unit second To set dimming finished duration time when physical switch used Ex When setting is 2 it will take 2 seconds from switch on ac...

Page 6: ...e mode 2 Choose the hex file to update the firmware 3 Wait 10 15 minutes for completing the OTA process 4 Result of OTA will show in Z Wave Controller log During the OTA process please DO NOT remove the power otherwise the firmware will be broken and the device will be nonfunctional Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None...

Page 7: ...se limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a particular installation I...

Reviews: