CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions.

Choosing a Suitable Location

1.

The suitable ambient temperature for the module/device is 0°C-
40°C

.

2.

Do  NOT  place   the  module/device  direct   under  sunlight,   in  a
humid   place   or   in   any   location   where   they   may   contact
moisture, dirt, dust.

3.

Do   NOT   place   the   module/device   where   exists   combustible
substances or any source of heat, fires, radiators, boiler etc.

Disposal

This marking indicates that this product should not 
be disposed with other household wastes throughout
the EU. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable 
reuse of material resources. To return your used 
device, please use the return and collection systems
or contact the retailer where the product was 
purchased. They can take this product for 
environmentally safe recycling.

Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 
24257, Taiwan(R.O.C)

www.philio-tech.com

FCC Interference Statement

This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules.

These   limits   are   designed   to   provide   reasonable   protection

against harmful interference in a residential installation.

This   equipment   generates,   uses,   and   can   radiate   radio   fre-

quency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio commu-
nications.

However, there is no guarantee that interference will not occur

in a particular installation.

If this equipment does cause harmful interference to radio or

television   reception,   which   can   be   determined   by   turning   the
equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for
help.

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including

interference that may cause undesired operation.

FCC   Caution:  Any   changes   or   modifications   not   expressly   ap-
proved   by  the   party  responsible   for   compliance   could   void   the
user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.

7

Summary of Contents for PAD18

Page 1: ...re for firmware upgrade Specification Rating Rating 12 24VDC Max 70mA In Sensor 0 10VDC Push button Switch Potentiometers 100K Out 0 10VDC for controller load RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 4MH 869 85MHz EU 922 5MHz 923 9MHz 926 3MHz JP 920 9MHz 921 7MHz 923 1MHz TW KR Thai SG Transceiver RF Maximum Power Peak 10dBm Peak RF Maximum Power Average 10dBm Averag...

Page 2: ...R TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK For Instruction to http www philio tech com Danger of Electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Locati...

Page 3: ... process please type in the first five digits of DSK string or scan the QR code The QR Code can be found on PAD18 or in the box Ex DSK 18112 24021 48001 62259 57092 27453 08187 47408 2 PAD18 is supported with SmartStart it can be added to Z Wave network by scanning the Z Wave QR code on the product 3 Without further actions PAD18 will be auto matically included in a certified Z Wave Controller wit...

Page 4: ...Wave system PAD18 responds to both Basic Command Class and Multilevel Switch Command Class However if PAD18 is included as a secure node it responds only to the security encapsulation command of Basic Command Class and Multilevel Switch Command Class The Basic Command Class is mapped according to the follow ing table Basic Command Mapped Command Basic Set Value Multilevel Switch Set Value Basic Re...

Page 5: ...nimum level 5 Output Min Level 1 0 0 Maximum level 1 To set dimming level minimum value Dimming level will directly go to 0 when dimming value is lower than the setting value Setting value Cannot be higher than the Maximum level 6 Basic Duration Config 1 2 0 127 Unit second To set dimming finished duration time when physical switch used Ex When setting is 2 it will take 2 seconds from switch on ac...

Page 6: ...e mode 2 Choose the hex file to update the firmware 3 Wait 10 15 minutes for completing the OTA process 4 Result of OTA will show in Z Wave Controller log During the OTA process please DO NOT remove the power otherwise the firmware will be broken and the device will be nonfunctional Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None...

Page 7: ...se limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a particular installation I...

Reviews: