max node of group:5
Group 2 name: Doorlock Op
Group 2 command list:
COMMAND_CLASS_DOOR_LOCK_V2,
max node of group:5
Z-Wave Configuration Settings
NO
Name
Def
Valid
description
1
RFvoice
setting
0x01
0x00 &
0x01
If set value to 0x00, RF
setting can let voice turn off
Notice 1: Always REMOVE a Z-Wave
TM
device before trying to
add it to a Z-Wave
TM
network.
Notice 2: if battery level less than 4.3V, doorlock can run
shut down mode. Touch panel operation can be stop until change
battery.
Notice 3: keypad locking function will be invalid when usercode all
deleted, the lock can be operated by key during that time.
Notice 4: This product can be operated in any Z-Wave network
with other Z-Wave certified devices from other manufacturers. All
non-battery-operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the
network.
II. Z-Wave
TM
Message Report
When you lock or unlock the door, the device will report the door
lock status as event to controller.
* Door Lock Status Report:
When you lock or unlock the door, the device will unsolicited to
send the report to the nodes in the group 1.
Door Lock Operation Report (V2)
Unlock
Current Door Lock Mode: Door Unsecured=00
Lock
Current Door Lock Mode: Door Secured=FF
unknow
Current Door Lock Mode: Door Secured=FE
VIII. Over the Air Firmware Update
The device supports the Z-Wave firmware update via OTA.
Let the Z-Wave
TM
Controller into the firmware update mode, chose
the hex file to update. Wait for 10~15 minutes.
At that time, please don't remove the battery, otherwise it will
cause the firmware broken, and the device will no function.
Result will show in Z-Wave
TM
Controller log.
X. Z-Wave Supported Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_VERSION
*
COMMAND_CLASS_NOTIFICATION
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC
*