background image

7

Summary of Contents for PSA03

Page 1: ...tion specifically to remotely control applications in residential and light commercial environments The technology uses a low power RF radio embedded or retrofitted into home electronics devices and systems such as lighting home access control entertainment systems and household appliances Notice if user use some command it have to check device is security bootstrap otherwise some command cannot i...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...do OPERATING INSTRUCTION no 1 door handling identification process Reset 1 Press the Restore function in section OPERATING INSTRUCTION no 10 2 Device can send reset locally notification note Please use this procedure only when the network primary controller is missing or otherwise inoperable Lock 1 Z WaveTM Controller use Command Class Door Lock 2 Use Command Door Lock Operation Set 3 Set value to...

Page 10: ...vice can auto include 2 SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on the product providing SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of minutes On in the network vicinity notice1 user must check device have be exclude notice2 the QR Code is printed on a mate...

Page 11: ... Message Report When you lock or unlock the door the device will report the door lock status as event to controller Door Lock Status Report When you lock or unlock the door the device will unsolicited to send the report to the nodes in the group 1 Door Lock Operation Report V2 Unlock Current Door Lock Mode Door Unsecured 00 Lock Current Door Lock Mode Door Secured FF unknow Current Door Lock Mode ...

Page 12: ...d three short beeps are emitted Cause Wrong door handling or change of the door handling in the memory Solution Press the R button to restore the system to factory default setting and re execute door handling identifying process 4 Although succeeded in the first execution of the door handling identifying process the latch does not work Feeling that the motor runs powerlessly the latch bolt is stuc...

Page 13: ... Average Transmission Range Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject to change and improvement without notice FCC ID RHHPSA03 CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions Choosing a Suitable Location 1 Do not locate the Module facing direct sun...

Page 14: ...rence to radio or tele vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the fol lowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected C...

Reviews: