background image

three times.

3. After add successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Remove

1. Have Z-Wave

TM

 Controller entered remove mode.

2. Hold down the central key, then press the top-right 

key three times within 1.5 seconds to enter the 

remove mode.Node ID has been excluded.

Note: PSR03-C is removed by pressing panic key 

three times.

Reset

1. Hold down the central key, then press the top-right 

key four times within 1.5 seconds and do not 

release the top-right key in the 4

th

 pressed, and the

LED will light ON.

Note: PSR03-C is reset by pressing panic key four 

times within 1.5 seconds and do not release the 

top-right key in the 4

th

 pressed.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the keys. If successful, 

the LED will light ON one second. Otherwise, the 

LED will flash once.

3. IDs are remove and all settings will reset to factory 

default.

Association 1. Have Z-Wave

TM

 Controller entered association 

mode.

2. Hold down the central key, then press the top-right 

key three times within 1.5 seconds to enter the 

association mode.

Note: PSR03-B supports 9 groups. Group 1 is for 

receiving the report message, like AV controls, battery 

status. Group 2 to group 9 are for lighting group 

control, the device will send the “Basic Set” command 

to these groups. And each group support 4 nodes 

maximum.

PSR03-A supports 3 groups. The group 1 is for 

receiving the report message. Group 2, 3 are for 

lighting group control. Each group supports 4 nodes.

Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-

Wave

TM

  Controller means “

Remove

” or “

Exclusion

”.

Failed or success in including/excluding the node ID can be 

viewed from Z-Wave

TM

 Controller.

Notice 1: 

 The device can not work normally in the first time.

 

Please 

activate the battery before the first use.

Notice 2:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network.

Notice 3:

 When the device into NWI mode, the NWI mode will timeout

after 30 seconds. You can Hold down the central key, then press the 

top-right key three times within 1.5 seconds to abort the NWI mode.

Function Control

Remote PSR03 can control AV device via Z-Wave-to-IR extender and

lighting groups ON/OFF.

PSR03-B has five keys on the device. The central one has group-button

switching and special function, the others are control keys.

There are two group-buttons that can be switched by pressing central 

key. When the device is switched to group-button 1, LED will light on 

with red color for 3 seconds. When the device is switched to group-

button 2, LED will light on with green color.

PSR03-A has three keys on the device. The central one has panic 

function and the others are control keys.

PSR03-C has panic function.

Summary of Contents for PSR03-A

Page 1: ...work will act as repeaters regardless of vendor to increase reliability of the network The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transm...

Page 2: ...nd the Basic Set command to these groups And each group support 4 nodes maximum PSR03 A supports 3 groups The group 1 is for receiving the report message Group 2 3 are for lighting group control Each group supports 4 nodes Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Failed or success in i...

Page 3: ...Button 2 Key Top left Command 0x0013 Universal Label Play Key Bottom left Command 0x0014 Universal Label Stop Key Top right Command 0x0016 Universal Label Fast Forward Key Bottom right Command 0x0017 Universal Label Rewind PSR03 A The left key controls Volume Up 0x0003 and the right key controls Volume Down 0x0002 Simple AV Control Set V4 Key Left Command 0x0003 Universal Label Volume Up Key Right...

Page 4: ...nds for receive the setting commands To wake up the device immediately please hold down the central key and press the top right key once or just press the key once if the device is PSR03 C The device will wake up 10 seconds Z WaveTM Message Report When the panic triggered the device will report the trigger event and also report the battery status Panic Report When the central key is held down over...

Page 5: ...date via OTA Let the controller into the firmware update mode and then wake up the device to start the update After finish the firmware download the LED will start flash in every 0 5 second Wait the LED stop flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Security Network The device support the security function When the device included with a ...

Page 6: ...All Setting the BASIC command value to turn on the light in the association group 3 0 means using the value of configuration 2 to set 84 Association Group 4 Basic Set Level 0 All Setting the BASIC command value to turn on the light in the association group 4 0 means using the value of configuration 2 to set 85 Association Group 5 Basic Set Level 0 All Setting the BASIC command value to turn on the...

Page 7: ...JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 0o C 40o C For indoor use only Specifications subject to change without notice due to continuing product improvement FCC ID RHHPSR03 Disposal This marking indicates that this product should not be disposed with other household wastes throug...

Page 8: ...t to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mod...

Reviews: