* AV Control

PSR03-B:
In Group-Button 1(Red LED), the top-left key and bottom-left key 
control Volume Up(0x0003) and Volume Down(0x0002), and the top-
right key and the bottom-right key control Channel Up(0x0004) and 
Channel Down(0x0005). 
In Group-Button 2 (Green LED), the top-left key and the bottom-left 
key control Play(0x0013) and Stop(0x0014), and the top-right key and 
the bottom-right key control Fast Forward(0x0016) and 
Rewind(0x0017).

Simple AV Control Set (V4)

Group-Button 1

Key: Top-left

Command: 0x0003

Universal Label: Volume Up
Key: Bottom-left

Command: 0x0002

Universal Label: Volume Down
Key: Top-right

Command: 0x0004

Universal Label: Channel Up
Key: Bottom-right

Command: 0x0005

Universal Label: Channel Down

Group-Button 2

Key: Top-left

Command: 0x0013

Universal Label: Play
Key: Bottom-left

Command: 0x0014

Universal Label: Stop
Key: Top-right

Command: 0x0016

Universal Label: Fast Forward
Key: Bottom-right

Command: 0x0017

Universal Label: Rewind

PSR03-A:

The left key controls Volume Up(0x0003) and the right key controls

Volume Down(0x0002)

Simple AV Control Set (V4)
Key: Left

Command: 0x0003

Universal Label: Volume Up
Key: Right

Command: 0x0002

Universal Label: Volume Down

* Lighting Group Control

PSR03-B:

Each group-button controls four lighting groups through keys around 

the central key. Switch ON/OFF the lighting groups by pressing those 

keys once/twice quickly. For example, if you want to turn on lighting 

group 1, press central key to switch to mode 1(Red LED) then press the

top-left key once. If you want to turn off lighting group 7, press the 

central key to switch to mode 2(Green LED) then press the bottom-left 

key twice quickly. 

Summary of Contents for PSR03-A

Page 1: ...work will act as repeaters regardless of vendor to increase reliability of the network The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transm...

Page 2: ...nd the Basic Set command to these groups And each group support 4 nodes maximum PSR03 A supports 3 groups The group 1 is for receiving the report message Group 2 3 are for lighting group control Each group supports 4 nodes Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Failed or success in i...

Page 3: ...Button 2 Key Top left Command 0x0013 Universal Label Play Key Bottom left Command 0x0014 Universal Label Stop Key Top right Command 0x0016 Universal Label Fast Forward Key Bottom right Command 0x0017 Universal Label Rewind PSR03 A The left key controls Volume Up 0x0003 and the right key controls Volume Down 0x0002 Simple AV Control Set V4 Key Left Command 0x0003 Universal Label Volume Up Key Right...

Page 4: ...nds for receive the setting commands To wake up the device immediately please hold down the central key and press the top right key once or just press the key once if the device is PSR03 C The device will wake up 10 seconds Z WaveTM Message Report When the panic triggered the device will report the trigger event and also report the battery status Panic Report When the central key is held down over...

Page 5: ...date via OTA Let the controller into the firmware update mode and then wake up the device to start the update After finish the firmware download the LED will start flash in every 0 5 second Wait the LED stop flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Security Network The device support the security function When the device included with a ...

Page 6: ...All Setting the BASIC command value to turn on the light in the association group 3 0 means using the value of configuration 2 to set 84 Association Group 4 Basic Set Level 0 All Setting the BASIC command value to turn on the light in the association group 4 0 means using the value of configuration 2 to set 85 Association Group 5 Basic Set Level 0 All Setting the BASIC command value to turn on the...

Page 7: ...JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 0o C 40o C For indoor use only Specifications subject to change without notice due to continuing product improvement FCC ID RHHPSR03 Disposal This marking indicates that this product should not be disposed with other household wastes throug...

Page 8: ...t to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mod...

Reviews: