background image

The lighting groups are not equal to association groups. The relation 

between lighting groups and association groups is shown below.

Lighting Group Control

Group-Button 1

Top-left Key

Top-right Key 

Bottom-left Key

Bottom-right Key

Lighting group 1 (Association group 2)

Lighting group 2 (Association group 3)

Lighting group 3 (Association group 4) 

Lighting group 4 (Association group 5)

Group-Button 2

Top-left Key

Top-right Key 

Bottom-left Key

Bottom-right Key

Lighting group 5 (Association group 6)

Lighting group 6 (Association group 7)

Lighting group 7 (Association group 8) 

Lighting group 8 (Association group 9)

PSR03-A:

Only has one group-button which controls two lighting groups.

Lighting Group Control
Left Key

Right Key 

Lighting group 1 (Association group 2)

Lighting group 2 (Association group 3)

Notice: 

For switch AV control or lighting group control function please 

setting the configuration No.7 bit 0. 

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

To wake-up the device immediately, please hold down the central key,

and  press the top-right  key once or just press the  key once  if the

device is PSR03-C. The device will wake-up 10 seconds.

Z-Wave

TM

 Message Report

When the panic triggered, the device will report the trigger event and

also report the battery status.

* Panic Report:

When the central key is held down over  

2

  seconds, the device will

unsolicited to send the report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Emergency Alarm (0x0A)

Event: Contact Medical Service (0x03)

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Notice

:  The configuration NO. 10 could be setting to zero to disable

the auto report. 

Activate the power

The device can not work normally in the first time. Please activate the

battery  through  micro   USB  before  the   first  use.  After   the  device  is

activated by connecting to micro USB, the device will start charging and

LED will light on with red color. If the battery is full charged, LED will

Summary of Contents for PSR03-A

Page 1: ...work will act as repeaters regardless of vendor to increase reliability of the network The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transm...

Page 2: ...nd the Basic Set command to these groups And each group support 4 nodes maximum PSR03 A supports 3 groups The group 1 is for receiving the report message Group 2 3 are for lighting group control Each group supports 4 nodes Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Failed or success in i...

Page 3: ...Button 2 Key Top left Command 0x0013 Universal Label Play Key Bottom left Command 0x0014 Universal Label Stop Key Top right Command 0x0016 Universal Label Fast Forward Key Bottom right Command 0x0017 Universal Label Rewind PSR03 A The left key controls Volume Up 0x0003 and the right key controls Volume Down 0x0002 Simple AV Control Set V4 Key Left Command 0x0003 Universal Label Volume Up Key Right...

Page 4: ...nds for receive the setting commands To wake up the device immediately please hold down the central key and press the top right key once or just press the key once if the device is PSR03 C The device will wake up 10 seconds Z WaveTM Message Report When the panic triggered the device will report the trigger event and also report the battery status Panic Report When the central key is held down over...

Page 5: ...date via OTA Let the controller into the firmware update mode and then wake up the device to start the update After finish the firmware download the LED will start flash in every 0 5 second Wait the LED stop flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Security Network The device support the security function When the device included with a ...

Page 6: ...All Setting the BASIC command value to turn on the light in the association group 3 0 means using the value of configuration 2 to set 84 Association Group 4 Basic Set Level 0 All Setting the BASIC command value to turn on the light in the association group 4 0 means using the value of configuration 2 to set 85 Association Group 5 Basic Set Level 0 All Setting the BASIC command value to turn on the...

Page 7: ...JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 0o C 40o C For indoor use only Specifications subject to change without notice due to continuing product improvement FCC ID RHHPSR03 Disposal This marking indicates that this product should not be disposed with other household wastes throug...

Page 8: ...t to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mod...

Reviews: