background image

light on with green color. 

When device is charging, it will send Wake Up Notification to controller

minutely.

* Battery Power Check

When any keys around the central key is pressed, the device will check

the battery power. If the power level is too low, the red LED will flash

once   after   pressing.   Please   charge   the   device   through   micro   USB

immediately.

* NWI

When the device is activated, the device will check is it already adding

to the network? If doesn't, it will auto start the NWI mode. The LED

will flash in every second and continue 30 seconds. Until timeout or the

device successful to add by controller. Users can hold down the central

key, then press the top-right key three times within 1.5 seconds to

abort the NWI mode.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.

Let the controller into the firmware update mode, and then wake up

the device to start the update.

After finish the firmware download, the LED will start flash in every 0.5

second. Wait the LED stop flash, the firmware update is succeeded.  

Caution

: Do not running the OTA when the battery is running low.

Security Network

The device support the security function. When the device included

with a security controller, the device will auto switch to the security

mode. In the security mode, the follow commands need using Security

CC wrapped to communicate, otherwise it will not response.

COMMAND_CLASS_BATTERY

COMMAND_CLASS_SIMPLE_AV_CONTROL_V1

COMMAND_CLASS_NOTIFICATION_V4

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_WAKE_UP_V2

Z-Wave Configuration Settings

Notice:

 

* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still   keep,   don't   reset   to   factory   default.   Unless   the   user   execute   the
“RESET” procedure.

Summary of Contents for PSR03-A

Page 1: ...work will act as repeaters regardless of vendor to increase reliability of the network The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transm...

Page 2: ...nd the Basic Set command to these groups And each group support 4 nodes maximum PSR03 A supports 3 groups The group 1 is for receiving the report message Group 2 3 are for lighting group control Each group supports 4 nodes Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Failed or success in i...

Page 3: ...Button 2 Key Top left Command 0x0013 Universal Label Play Key Bottom left Command 0x0014 Universal Label Stop Key Top right Command 0x0016 Universal Label Fast Forward Key Bottom right Command 0x0017 Universal Label Rewind PSR03 A The left key controls Volume Up 0x0003 and the right key controls Volume Down 0x0002 Simple AV Control Set V4 Key Left Command 0x0003 Universal Label Volume Up Key Right...

Page 4: ...nds for receive the setting commands To wake up the device immediately please hold down the central key and press the top right key once or just press the key once if the device is PSR03 C The device will wake up 10 seconds Z WaveTM Message Report When the panic triggered the device will report the trigger event and also report the battery status Panic Report When the central key is held down over...

Page 5: ...date via OTA Let the controller into the firmware update mode and then wake up the device to start the update After finish the firmware download the LED will start flash in every 0 5 second Wait the LED stop flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Security Network The device support the security function When the device included with a ...

Page 6: ...All Setting the BASIC command value to turn on the light in the association group 3 0 means using the value of configuration 2 to set 84 Association Group 4 Basic Set Level 0 All Setting the BASIC command value to turn on the light in the association group 4 0 means using the value of configuration 2 to set 85 Association Group 5 Basic Set Level 0 All Setting the BASIC command value to turn on the...

Page 7: ...JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 0o C 40o C For indoor use only Specifications subject to change without notice due to continuing product improvement FCC ID RHHPSR03 Disposal This marking indicates that this product should not be disposed with other household wastes throug...

Page 8: ...t to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mod...

Reviews: