control the ON/OFF

 

Switch of the load 
attached

 

has its own ON/OFF 
switch

 

2. The switch is protected

 

2. Unprotected the switch or follow the 

instruction of protection.

 

The Switch LED 
illuminating, but the 
Detector cannot control

 

the Switch

 

1. Not carry out 

association

 

2. Same frequency 

interference

 

1. Carry out association

 

2. Wait for a while to re-try

 

LED keep flashing, but 
cannot control

 

Overload occurs

 

Remove the load attached or check 
max. load cannot exceed 13A (Resistive 
load)

 

 

For Instruction to http:// www.philio-tech.com

    

 
 
 
 
 
 
 
 
 
 

Socket Type

 

Since the socket type for each country in Europe varies, refer to the outline for each 
socket suited for each country as follows:

 

 

 
 
 
 
 
 
 
 

    PAN16-1 German              PAN16-2 French                      PAN16-3 U.K.                                     

 

                                                                                                             

 

           

 

Note

Please make sure that the intensity of the plug of the electrical device must be 

16A and have same head as the enclosed plug before inserting to the socket.

 

 

 

 
 

DANGER

    

Danger of electrocution!

 

 

All works on the device may be performed only by a qualified and licensed electrician. 

Observe national regulations. 

 

Any works introducing changes into the configuration must be always performed with 
disconnected voltage. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PAN16

Page 1: ...h quickly However unplug and re connect the switch will reset its overload condition to normal status Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zw...

Page 2: ...d 13A Resistive load For Instruction to http www philio tech com Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows PAN16 1 German PAN16 2 French PAN16 3 U K Note Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the...

Page 3: ...n mode Remove 1 Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the ev...

Page 4: ...he Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Comman...

Page 5: ...power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 ...

Page 6: ...AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size ...

Page 7: ... 3 5 Restore switch state mode Whenever the AC power return from lost PAN16 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is...

Page 8: ...nt by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 6 Command Classes The Switch supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS...